Chrosziel MagNum MN-100 Manuel de référence rapide - Page 2
Parcourez en ligne ou téléchargez le pdf Manuel de référence rapide pour {nom_de_la_catégorie} Chrosziel MagNum MN-100. Chrosziel MagNum MN-100 2 pages. Single-channel wireless lens control system
Menu Navigation
Power button, press for more than 2
seconds to switch hand unit off; can
be used to exit a sub menu as well
Select menu item (up)
Press center button to enter set up
menus
Edit values (left = -; right = +)
Select menu item (down)
Set Up the Record Start/Stop Trigger*
Select whether hand unit with ID 1 or
Record Trigger
2 can trigger the record signal
Enabled ID:
1
Matching :
Select mode entry and modify trigger
Mode: < Pulse >
mode with -/+ buttons
Start
Stop
*Setting is stored in the motor box in
Save&Exit
Cancel
the non volatile memory and is
editable on hand unit 2 as well
Set Up Motors & Servo Lens Control
Motor 1: Enter configuration menu of
Motor Setup
the motor output
Motor 1 (F)
Motor 2: No support in combination
Motor 2 (I/Z)
with MN-100 motor controller!
Servo Lens Setup
Servo Lens Setup*: No Support on
F:
on
I:
on
Z:
off
MN-100 motor controller!
< Back
*Setting is stored in the motor box in the non-volatile memory
Calibrating motors in manual "Photo Lens" mode
Unlike commonly used lenses in the film industry the lenses for still cameras do not feature physical end stops on their gears. Therefore it is
not possible to calibrate so-called photo lenses by the motor controller automatically. The MagNum motor controller addresses this issue by
allowing a desired motor socket to be configured as "Lens Type = photo". The manual procedure is as follows:
mount motor as normal on the support rod and engage it to the lens in a middle position of the available range of movement
press calibration button once; motor LEDs start flashing fast but motor will not start moving on its own as it would in "Cine" mode
move motor by hand by manually turning lens to both of the limits (infinite & near) of the lens gear
turn motor back to a middle position after
press calibration button a second time , motors will now start moving measuring automatically lens parameters between the two chosen
end points
after this calibration is finished
Hints:
As most motors show a certain amount of play/backlash, turn the motor a little further than normally necessary in order to compensate this
play regarding the correct end stops on both limits.
Some motors do not allow turning manually in both directions – in this case engage the motor on one limit and turn the motor just in the
direction to the opposite limit.
Main Screen
Display of power supply voltage on
Cam. Pow.: 13.5V
receiver side*
Data always visible, from left to right:
ID 1
Battery indicator
Hand unit ID (can be 1 or 2)
RF signal strength indicator
Bidirectional
link
indicator:
Green = connection OK – may go
red intermittently
*Display can be disabled/enabled on menu entry "Display Options"
Setup Scales - Reverse Scale Direction*
If switched to "On", wheel or slider
Reverse Wheel
operate reversed. Operation direction
off
depends on how motors are mounted
and on the preferences of the user
Reverse Slider
off
*Setting is stored in the hand unit and
is independent from setting in second
Save&Exit
Cancel
hand unit.
Set Up Motor Output*
M1 Set Up
Link to: Assigned function (Focus / or
Iris)
F
Link to
Mode: Switch to dimmer mode here.
Mode
motor
Dimmer cable can be controlled.
Range
Lens
Range: Switch to 3D Rig mode if
Direction
norm
required
Play/ Safety
0 / 0
Direction : Reverse motor direction
Full
Torque
Play/Safety: Modify play (backlash)
Lens Type
Photo
compensation for heavily used motors
Save&Exit
Cancel
with a large amount of play in the
gearbox.
Modify the safety distance, the motor stays away from the
mechanical Lens End Stops (S3D Rigs). Torque: Reduce torque of
the motor to mid (50%) or low (25%).
Lens Type: Cine = End stops will be calibrated automatically; Photo
= End stops are calibrated manually.
*Setting is stored in the motor box in the non-volatile memory and is
editable on hand unit 2 as well
Setup Screen
(press Center Button from Main Screen)
Switch LED swan-neck light on/off
Light ON/OFF
Select radio channel and range
Radio Channel
(MHz or GHz)
Record Trigger
Select camera record start/stop mode
Scales
Reverse wheel &/or slider operating
Calibrate Motors
direction
Start motor calibration remotely
Motor Setup
Motor setup (torque ; direction; play
Set Up Hand Unit
correction ...)
Select hand Unit ID, serial socket
mode, calibrate the hand wheel &
slider, assign user keys
Start Motor Calibration remotely
Select a motor with up/down buttons and
Motor Calibration
then
press center button of the keypad,
automatic or manual end stop calibration is
Cal. Focus
initiated.
Cal. Iris (Zoom)
< Done
Setup Hand Unit
Ctrl. ID: Switch the hand unit ID to 2 if
Set Up Hand Unit
two controllers shall be used (split
Ctrl. ID < >
1
functions F & I to two controllers). ID1
controls F & I by default. If a second
Left-Handed
no
unit is set to ID 2, this unit will take
Serial Socket
over control of motor I by its hand
Display Options
wheel if MN-200R motor controller is
Load Defaults
used.
You must not have more than one
hand unit set to the same ID!
Wheel/Slider Cal.
Left-Handed: If "yes", the Display is
< Back
rotated by 180° in order to make left-
handed operation more easy
Serial Socket: No support!
Display Options: Select, whether several displays shall appear on
the main screens info area (i.e. Cam.-Power)
Wheel/Slider Cal.:
Basic calibration of the hand wheel to its
respective mechanical operating range
Spreading of the Wheel
Spreading is done by pressing one of the user keys 1 .. 4. Spreading function needs to be assigned to the desired user keys*. Default mode
is*: U1-4 spread the wheel scale. So there are four different spreading setups available.
To set a spreading:
a) Move wheel to the desired first starting point, press a user key for more than 1 second and keep pressing during the procedure
b) Respective yellow LED starts flashing
c) Move wheel to the desired second point, release the user key
d) Spreading is applied between the two points, respective yellow LED lights up continuously
To switch off a spreading: Press the user keys for which a spreading is activated less than 1 second, respective yellow LED goes off.
To recall a formerly programmed spreading: Press the same user key again for less than 1 second.
*Currently the assignment of spreading function is fixed to the default set up. Later software versions will allow to assign different functions
to the 4 user keys.
Set the Frequency Range and the Radio Channel
Set Radio
Chan.:
8
Freq. :
2422.75
Spectrum
Please note: When this screen is visible the MagNum wireless
connection is temporarily disconnected as the hand unit scans
through all available RF channels at this time searching for
possible frequencies. For GHz range (Channels 5 - F) internal
antennas are used.
Frequency Table:
Channel
Center Frequency
0
n.a.
1
n.a.
2
n.a.
3
n.a.
4
n.a.
5
2.400.75 GHz
6
2.40375 GHz
7
2.40975 GHz
8
2.42275 GHz
9
2.44075 GHz
A
2.44375 GHz
B
2.44975 GHz
C
2.46275 GHz
D
2.47075 GHz
E
2.47375 GHz
F
2.48175 GHz