5.2. ELECTRIC APPLIANCES
5.2.1. ELECTRICAL CONNECTION (Fig. 4A -Table A).
IMPORTANT! Before connecting, make sure the mains
voltage and frequency match that given on the dataplate.
• To access the terminal board, remove the appliance con-
trol panel by removing the fixing screws (fig. 4A 1-2).
• Connect the power cable to the terminal board as shown in the
wiring diagram attached to the appliance.
• Secure the power cable with the cable gland.
IMPORTANT! The manufacturer declines any liability if the
safety regulations are not respected.
5.2.2. POWER CABLE
Unless otherwise specified, our appliances are not equipped with
a power cable. The installer must use a flexible cable having
characteristics at least equivalent to H05RN-F rubber-insulated
type cables. Protect the cable section outside the appliance with a
metal or rigid plastic pipe.
5.2.3. CIRCUIT BREAKER
Install a circuit breaker ahead of the appliance. Contact open-
ing distance and maximum leakage current must comply with
current regulations.
5.3.
EQUIPOTENTIAL NODE AND EARTH
CONNECTION
Connect the appliance to an earth; it must be included in an
equipotential node by means of the screw located at the front
right under the frame. The screw is marked with the symbol
.
Appliance max. leakage current is 1 mA/kW.
6. SAFETY THERMOSTAT
Some of our appliance models use a safety thermostat that
cuts in automatically when temperatures exceed a set value,
shutting off the gas supply (gas appliances) or the electricity
(electric appliances).
6.1. RESET
• Wait until the appliance has cooled down: a suitable tem-
perature for resetting is approx. 90°C.
• Press the red button on the safety thermostat body.
IMPORTANT! If resetting requires the removal of a protec-
tive part (e.g. control panel) this must be done by a special-
ised technician. Tampering with the safety thermostat invali-
dates the warranty.
7. FUSE REPLACEMENT
The electrical system protection fuse is located inside the
panel. To replace the fuse, unscrew the fuse holder cap and
remove it.
8. BEFORE LEAVING
Check all connection for gas leaks with soap and water. Do
not use a naked flame for detecting leaks. Ignite all burners
both individually and combined to ensure correct operation
of gas valves, burners and ignition. Turn gas taps to low flame
for each burner, individually and separately, when satisfied
with the appliance, please, instruct the user on the correct
method of operation. In case the appliancefails to operate
correctly after all checks have been carried out, refer to the
authorised service provider in your area.