INSTALLATION STEPS
8
4
Plumb In UV Filter
1. Use the Mounting Brackets to mount the UV Reactor to wood
or drywall. If mounting to an alternate material, you will need
to purchase the proper corresponding fasteners.
2. Plumb UV Filter and additional filtration add-ons into the
system at this time. Screw Post-Filter support brackets onto
the wall and attach filter. Use PVC pipe, elbows and reducers
to connect from Post-Filter to UV inlet.
3. Properly connect system together accordingly (slip fittings,
barbed fittings, NSF certified PVC glue, etc.). Ensure all parts
are flowing through in the correct direction of water flow.
4. Once installation is complete, allow proper time for glue
to dry according to manufacturer instructions.
5
Insert the Quartz Sleeve
DO NOT touch the Quartz Sleeve with your hands. Use
cotton gloves for this procedure as oils from hands can
leave residue on sleeve and UV Lamp blocking UV light.
1. Gently remove the Quartz Sleeve from packaging
and slide the sleeve into the UV Reactor. Align
the Quartz Sleeve so it's centered and gently
push it in to lock it into the internal centering
springs on the opposite end of the UV Reactor.
NOTE: Pushing too hard when the Quartz Sleeve is
not aligned can damage the Centering Springs.
2. Slide the O-Ring onto the Quartz Sleeve until
it is butted up against the UV Reactor.