2.8
Gas units type A1
These units are not designed to be fitted to a natural flue exhaust outlet.
The gas unit should be installed under a standard-compliant draft hood, as it requires an intake of at least 2 m3/h . kW of
thermal capacity.
The room in which it is installed should be adequately ventilated.
2.9
Operation check
- Start the unit according to the user instructions in Section 5.
- Make sure that there are no gas leaks.
- Check the ignition and inter-ignition of the pilot burner and main burner.
- Make sure the flue gases are discharged properly.
- Record on a sticker the gas type and device pressure for which the unit was calibrated and affix the sticker next to the
data label.
2.10 User information
Draw the user's attention to safety and daily maintenance rules.
Explain to the user how to operate and use the fryer by referring to the User Manual and show what changes were
made, if any. Leave a copy of this manual with the user.
2.11 Operating manual for the installing technician
Before starting the unit, verify that :
- The pilot flames are not set too high or too low.
- Thermostat elements turn off in less than 60 seconds.
- Burners have proper supply and nozzles operate normally.
- The safety sensor switches off at 210° (heat up the safety sensor using a lighter or similar device).
- Make sure that the user is familiar with the main safety points.
Only if all the previous points were found to be compliant and if the unit was installed in accordance with the rules, the
unit may be put into service, as described in the operating procedure.
Damage caused by non-observance of legal provisions and an assembly process that is non-compliant with the descri-
bed installation procedure may result in hazardous situations for which TEKNO-LAM disclaims all responsibility.
If installation is not performed by an authorised installer, the warranty will be invalidated.
In all cases, damaged or worn parts must be replaced with genuine spare parts and must be installed by an authorised
installer.
Any parts to be replaced under warranty must be returned to us no later than 8 days. In the event that any non-genuine
parts, accessories or safety devices have been installed, or if the device was not calibrated or repaired by an expert,
TEKNO-LAM will not grant you any warranty.
In case of any doubt concerning the procedure to be followed or any other questions, contact us :
- By phone : 0032/2532.10.30 (from 8h30 to 12h and from 12h30 to 16h30)
- By fax : 0032/2532.55.10 (24h/24h)
- By E-mail : [email protected]
The installation technician must observe the regulations in force
in the countries or regions where the appliance will be used
Should the user or installation technician fail to observe the instructions in this manual, the company disclaims all res-
ponsibility and no accident or malfunction caused by such non-observance shall be attributable to the manufacturer
8