Aquasana AQ-5200 Manuel d'instructions d'installation - Page 5
Parcourez en ligne ou téléchargez le pdf Manuel d'instructions d'installation pour {nom_de_la_catégorie} Aquasana AQ-5200. Aquasana AQ-5200 8 pages. Under counter water filter
Également pour Aquasana AQ-5200 : Instructions d'installation (5 pages)
6
Unit Installation: Select a
space under your sink for the
filter unit that is at least 12 inches
from the bottom of your cabinet
and allows for easy access to your
cold water supply and for filter
replacements. Use the mounting
holes located at the back of the unit
to mark the wall screw placements
with a pencil.
Center to center hole distances:
AQ-5100: 41mm
AQ-5200: 65mm
AQ-5300: 98mm
9
Connect the supply lines: push the
tubing into the inlet side and outlet side
of the housing. The tee fitting tube goes to the
inlet and the faucet tube goes to the outlet.
2
3
3
2
1
7
Use a 7/32" drill bit to drill
holes for the plastic anchors
provided. Carefully tap the
anchors into the drilled hole with
a hammer. Mount unit to the wall
with the screws.
For the AQ-5200 and AQ-5300 —
Pull the protective plastic strip
from the battery compartment.
The red LED should flash and beep
five (5) times to indicate that the
battery is installed correctly.
10
Turn the cold water on. Check for
leaks and proper installation: place a
towel under the filter unit and check for leaks.
Allow water to run for 10 minutes to flush
carbon fines.
Note: Never use oils to lubricate the O-rings;
O-rings come pre-lubricated.
Enjoy your filtered water!
2
2
1
8
Attach each sump
to the bottom of
the unit housing. Align
connection points,
push the sump up
and turn to the right.
Ensure that the sump
is locked in.