Panasonic WV-SP508 Manuel d'installation - Page 23

Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Panasonic WV-SP508. Panasonic WV-SP508 36 pages. Ip video cameras
Également pour Panasonic WV-SP508 : Spécifications (2 pages), Manuel d'installation (40 pages), Note d'intégration (8 pages)

Panasonic WV-SP508 Manuel d'installation

Camera mounting

The camera is mounted on the camera mount bracket (locally procured) and the safety wire is
secured.
IMPORTANT:
• The installation area shall be strong enough to hold the camera and camera mount bracket.
• The camera mount bracket (locally procured) shall be mounted on the foundation part of the
construction or a part with adequate strength.
• To prevent the mounting strength from becoming lower, do not use wooden screws to secure
the camera mount bracket (locally procured).
z
Secure the camera mount bracket (locally procured) to an installation position, and mount the
camera on the camera mount bracket.
Prepare mounting screws according to the material of the area where the camera mount brack-
et is to be installed. The installation method may be different depending on the material of the
area where the bracket is to be installed.
• When installing on steel: Fix with bolts and nuts (M6 or M8)
• When installing on concrete: Fix with anchor bolts (M6 or M8)
The mounting conditions of the camera mount bracket (locally procured) are described as follows:
Installation
position
On ceiling
On wall
IMPORTANT:
• Refer to the operating instructions of the
camera mount bracket (locally procured)
for the mounting angle of the camera
mount bracket for a ceiling or wall.
• When the camera mount bracket is mount-
ed on a wall, be sure to observe the
mounting height described on the illustra-
tion.
x
Secure the safety wire to the foundation part of the construction or a part with adequate
strength (minimum pull-out strength 196 N {44.06 lbf}).
Prepare the fixing screw according to the material of the area where the safety wire is to be fixed.
Recommended
screw
M6 or M8
M8
Screw quantity
3 pcs.
4 pcs.
Minimum pull-out
strength (per 1 pc.)
196 N {44.06 lbf}
921 N {207.05 lbf}
2 m 90 cm {9.5 feet}
or more
Floor