Panasonic WV-SW395 Manuel d'installation
Connection
Caution:
Before starting connection, make sure that the circuit breaker is switched off. Failure to observe this may cause fire,
electric shock, injury, or damage to the product.
Power cable
WV-SW395
8P alarm cable connector
• Power cable
Connect the power cable to the 24 V AC power supply using the 24 V AC power supply connector kit (accessory).
Important:
• The power supply of 24 V AC shall be insulated against 120 V AC (for U.S. and Canada) or 220 V - 240 V AC (for
Europe and other countries).
• Do not cut or process the network cable since the power is superimposed when using a PoE+ device for power sup-
ply. Besides, do not put an excessive weight on connected sections.
22
Brown
Blue
Green/Yellow
Network cable
Output cable for the
monitor used for
adjustment
External I/O cable
Microphone input cable (white)
Audio output cable (black)
ALARM IN1/DAY/NIGHT IN (black) (EXT I/O 1)
GND (brown)
ALARM IN2/ALARM OUT (red) (EXT I/O 2)
GND (orange)
ALARM IN3/AUX OUT (yellow) (EXT I/O 3)
GND (light blue or green)
Unused (blue)
Unused (purple)
To the power supply (24 V AC, 50 Hz/60 Hz)
GND
LAN cable (category 5e or better, STP*)
* PAL model only
Coaxial cable
(BNC)
8P alarm cable (accessory)
To a plug-in power type microphone
To an external powered speaker
To a PoE+ hub, PC, etc.
To the monitor used
for adjustment
To a sensor