HP 316095-B21 - StorageWorks Edge Switch 2/24 Note de mise à jour - Page 19

Parcourez en ligne ou téléchargez le pdf Note de mise à jour pour {nom_de_la_catégorie} HP 316095-B21 - StorageWorks Edge Switch 2/24. HP 316095-B21 - StorageWorks Edge Switch 2/24 19 pages. Edge switch release notes
Également pour HP 316095-B21 - StorageWorks Edge Switch 2/24 : Manuel de mise à jour (9 pages), Manuel (41 pages), Manuel (40 pages), Note de mise à jour (32 pages), Note de mise à jour (27 pages), Manuel (26 pages), Note de mise à jour (27 pages), Note de mise à jour (25 pages), Manuel d'instructions d'installation (24 pages), Note de mise à jour (23 pages), Note de mise à jour (23 pages), Note de mise à jour (22 pages), Note de mise à jour (23 pages), Note de mise à jour (19 pages), Note de mise à jour (18 pages), Manuel d'instructions (17 pages), Note de mise à jour (17 pages), Instructions de mise à niveau (16 pages), Manuel d'instructions (16 pages), Manuel d'instructions d'installation (16 pages), Note de mise à jour (16 pages), Note de mise à jour (17 pages), Note de mise à jour (17 pages), Note de mise à jour (11 pages)

HP 316095-B21 - StorageWorks Edge Switch 2/24 Note de mise à jour

Multiple FC HBA Ports in Separate Zones

Multiple FC HBA ports in the same host should be placed in separate zones, or
they might be perceived as potential targets (some HBAs log-in as both host and
target).

CTP Controls Port Lights

Port lights on the edge switch and director products are controlled by the CTP
functionality. Certain activities such as FW updates, IPLing the CTP, or switching
over to the backup CTP (Director) can cause these port lights to extinguish
momentarily until control is reasserted by the CTP. The actual FC traffic is not
affected during these times.
Support for Speed Auto-Negotiate
Currently, Speed Auto-Negotiate is not supported for HA and Failover SAN
configurations and is not recommended in general at this time. The speed should
be hard set to match the attached host or target port capability whenever possible.

Ports May Accumulate Spurious Events

A port may accumulate Invalid transmission word and Bit-Error Threshold Link
Incident events when a transceiver is poorly seated resulting in a poor ground
connection.
Workaround
Reseating the optical transceiver will correct the problem.
Edge Switch Release Notes
Known Issues
19