3.
If the power LED is on but the RPS status LED is off, an RPS input failure has occurred.
Verify the following items:
The switch is securely connected to the RPS.
The RPS is correctly working.
NOTE:
If the problem persists, contact the Hewlett Packard Enterprise technical support for help.
Configuration terminal problems
If the configuration environment setup is correct, the configuration terminal displays booting
information when the switch is powered on. If the setup is incorrect, the configuration terminal would
display nothing or garbled text.
No terminal display
If the configuration terminal displays nothing after the switch is powered on, verify the following
items:
The power supply is supplying power to the switch.
The console cable is correctly connected.
The console cable has no problem and the terminal settings are correct.
Garbled terminal display
If terminal display is garbled, verify that the following settings are configured for the terminal, for
example, HyperTerminal:
Baud rate—9,600.
Data bits—8.
Parity—none.
Stop bits—1.
Flow control—none.
Emulation—VT100.
25