AQUATECH LSM Manuel d'instructions - Page 6
Parcourez en ligne ou téléchargez le pdf Manuel d'instructions pour {nom_de_la_catégorie} AQUATECH LSM. AQUATECH LSM 12 pages. Level switch
1.
INSTALLATION INSTRUCTIONS
FOR LIQUID LEVEL SWITCH LSM, LSM-P3 & LSM-TT-B
1.1
GENERAL
These instructions are intended for the installer of this level switch. Please follow them carefully.
Failure to install the equipment as recommended below could invalidate the warranty.
1.2
ADDITIONAL WARNINGS & CAUTIONS
1.2.1 READ GENERAL SAFETY INFORMATION 0.0, WARNINGS 0.1 and CAUTIONS 0.2, 0.3 & 0.4
1.2.2 Units fitted with a 1/2" BSP parallel thread (LSM-P3) must not be installed into a taper
thread fitting otherwise the equipment will be damaged causing mechanical failure.
1.2.3 Pressure imposed on sensing probes must not exceed 1.0 Bar otherwise the equipment
will be damaged causing mechanical failure.
1.3
PROCEDURE
1.3.1 LOCATION
The level switch LSM is for wall mounting with brackets provided using separate probe unit/float
switches.
The level switch LSM-P3 can be installed through the tanks lid.
Ensure that the location provides adequate clear space for reasonable access to all parts. There
must be sufficient room to:-
1.3.2 FIXING
To install the level switch LSM-P3 in a tank lid either: -
a) drill a 20mm diameter clearance hole and use the back nut and washer provided, to ensure
water tight seal, or
b) install in a 1/2" BSP parallel thread and ensure a water tight seal.
1000 mm
Fig 1. Mechanical detail of Level switch LSM-P3
Aquatech-Pressmain Limited Instruction manual\Liquid Level Switch LSM
open control box lid;
withdraw level switch from tank.
105 mm
105 mm
1/2" BSP thread
Sensing Probes
60 mm
20 mm
Level Switch LSM
6