HP StorageWorks 2/16 - SAN Switch Note de mise à jour - Page 24

Parcourez en ligne ou téléchargez le pdf Note de mise à jour pour {nom_de_la_catégorie} HP StorageWorks 2/16 - SAN Switch. HP StorageWorks 2/16 - SAN Switch 32 pages. Fabric os commands
Également pour HP StorageWorks 2/16 - SAN Switch : Manuel de mise à jour (9 pages), Manuel d'instructions d'installation (20 pages), Manuel de l'utilisateur (22 pages), Notes de mise à jour du micrologiciel (14 pages), Note de mise à jour (16 pages), Manuel d'installation (14 pages), Note de mise à jour (10 pages), Manuel de référence rapide (5 pages)

HP StorageWorks 2/16 - SAN Switch Note de mise à jour
Documentation Updates
Table 4: Version 3.1.2 Error Messages Not Previously Available (Continued)
Severity & Message
Critical
DIAG-CMISA1, 1
Critical
DIAG-CMNOBUF, 1
Critical
DIAG-DATA, 1
Critical
DIAG-ERRSTAT (2LONG), 1
24
Probable Cause
An attempt to send a CMI message
from ASIC to ASIC failed. This
usually indicates an ASIC failure.
This message is generated by the
cmitest command, if problems
are found.
Port could not get any buffers. This
usually indicates an ASIC failure.
This message is generated by the
centralmemorytest command,
if problems are found.
Payload received by port did not
match payload transmitted. This can
be caused by a faulty cable or
deteriorated SFP. It can also indicate
deeper problems in the
motherboard or ASIC. This message
is generated by the
crossporttest or
portloopbacktest commands,
if problems are found.
Port Error Statistics counter is
nonzero, meaning a that a Frame
too long error was detected
when receiving frames. This can be
caused by a faulty cable or
deteriorated SFP. It can also indicate
deeper problems in the
motherboard or ASIC. This message
is generated by the
portloopbacktest or
spinsilk commands, if problems
are found.
Recommended Action
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
Check for a faulty cable or
deteriorated SFP. Replace the
cable or SFP if necessary.
If the problem persists:
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
Check for a faulty cable or
deteriorated SFP. Replace the
cable or SFP if necessary.
If the problem persists:
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
SAN Switch 2/16 Fabric OS 3.1.2 Release Notes