Closed defect summary
On disabling the proxy switch (FOS 6.0 ), no event received on the
SMIA agent side.
When HA sync was stopped, a SAN Director 2/128 did not output
the FW-1433 message.
For ISL_RDY mode, transmit credit is exceeds its limit at 250. It works
okay if required buffer is less than 250 (that is, 250km at 2G).
Fastwrite with tape pipeline, switch sent improper frame caused
tape job to fail.
For Tapepipelining the FCP RSP does not come from Fabric.
supportshow does not include portcfgvexport data for
VEX_Ports.
In some cases where an FCIP address is on a different subnet, a MAC
level broadcast is sent instead of the router's MAC.
Hot plug Core Blade with POST on, the blade comes up Faulty(51)
due to turbo RAM test failure.
Web Tools enable config option cannot configure the maximum
supported number of zones (2047).
Editing IPv6 prefix length from Web Tools does not work.
cfgdisable fails on MP Router 400 running in XRC configuration.
FIPS related changes required in response to a FIPS audit.
SRDFA suspends in a fastwrite environment.
A device disappears after server reboot in a FICON environment.
FC4-48 blade drops frame on the 4/256 SAN Director on ports that
are routed through Director ports above 256.
IBM FICON Qual. The FW message needs to specify the blade number
when a port blade faults in the DC Director.
porttest not working.
Need to add a delay to the PLOGI ACCept for all well known ad-
dresses.
Operator-disabled ports are displayed as marginal under specific
conditions.
firmwaredownload pre-install script fails to detect that QoS links
are active prior to a downgrade.
Phantom power supply faults logged against the DC Director.
Power supply status incorrectly identified as marginal when power
supplies are in certain slots.
Solution
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
HP StorageWorks Fabric OS 6.1.0h release notes