HP StorageWorks SAN Switch 2/8 EL Note de mise à jour - Page 24

Parcourez en ligne ou téléchargez le pdf Note de mise à jour pour {nom_de_la_catégorie} HP StorageWorks SAN Switch 2/8 EL. HP StorageWorks SAN Switch 2/8 EL 26 pages. San switch 2/8 version 3.0.2k release notes
Également pour HP StorageWorks SAN Switch 2/8 EL : Note de mise à jour (16 pages)

HP StorageWorks SAN Switch 2/8 EL Note de mise à jour
Issues and Workarounds
JNI 6460 HBA Negotiation
If a port speed is changed to 1 Gb and then back to AN, the JNI 6460 HBA
negotiates at 1 Gb instead of 2 Gb.
To fix this problem, set the port speed to 2 Gb, or disconnect the cable and then
reconnect it. The JNI 6460 HBA will again negotiate at 2 Gb.
configdownload Command
If there are errors in the security database and security is enabled, the
configdownload command will fail.
To fix this problem, resolve the security database errors and reissue the
configdownload command.
Login as root
If you log in as the root account in order to launch switch admin, any admin/user
account information changes you make will not be applied to the switch.
To avoid this problem, log in as an admin level account.
syslog Message not Forwarded
If Quiet mode is enabled, syslog will no longer forward messages to any syslog
configured management stations. (Note that the error messages are still available
in the Error Log [for example, errShow, errDump].)
To avoid this problem, do not use Quiet mode.
Relocating Switch Port Cable
Relocating the switch port cable causes the loss of dynamic end-to-end monitors
residing on the port.
Dynamic end-to-end monitors do not move with the device. To avoid the problem,
when relocating the device, delete the monitor and add it back manually.
24
SAN Switch 2/8 Version 3.1.x Release Notes