Également pour HP StorageWorks XP10000 - Disk Array : Note de mise à jour (13 pages), Manuel de l'administrateur (50 pages), Manuel de configuration (40 pages), Manuel de configuration (40 pages), Manuel de configuration (36 pages), Manuel de configuration (36 pages), Manuel de configuration (30 pages), Manuel de configuration (36 pages), Note de mise à jour (5 pages), Manuel de configuration du système (49 pages), Manuel de configuration du système (43 pages), Manuel de configuration du système (42 pages), Manuel de configuration du système (35 pages), Manuel de configuration (46 pages), Manuel de configuration (46 pages), Manuel de configuration (40 pages), Manuel de configuration (44 pages), Manuel de configuration (38 pages), Manuel de configuration (34 pages), Manuel de configuration (30 pages), Manuel de configuration (30 pages), Manuel de configuration (42 pages), Manuel de l'utilisateur (30 pages)

HP StorageWorks XP10000 - Disk Array Manuel de configuration
The following host group modes (options) are available for Solaris:
Table 1 Host group modes (options)
Host
Group
Mode
Function
Veritas DBE+RAC Database Edition/Ad-
vanced Cluster for Real Application Clusters
2
or if Veritas Cluster Server 4.0 or later with
I/O fencing function is used.
7
Reporting Unit Attention when adding LUN
CAUTION:
Changing host group modes for ports where servers are already installed and configured is disruptive
and requires the server to be rebooted.

Setting the system option modes

The HP service representative sets the system option mode(s) based on the operating system and
software configuration of the host. Notify your HP representative if you install storage agnostic software
(such as backup or cluster software) that may require specific settings.

Configuring the Fibre Channel ports

Configure the disk array Fibre Channel ports by using XP Remote Web Console (shown) or XP
Command View Advanced Edition Software. Select the settings for each port based on your storage
area network topology. Use switch zoning if you connect different types of hosts to the array through
the same switch.
12
Installing and configuring Sun Solaris for the XP disk array
Default
Comments
Previously MODE186
Inactive
Do not apply this option
to Sun Cluster.
Previously MODE249
Inactive