HP StorageWorks XP10000 - Disk Array Manuel de configuration - Page 12

Parcourez en ligne ou téléchargez le pdf Manuel de configuration pour {nom_de_la_catégorie} HP StorageWorks XP10000 - Disk Array. HP StorageWorks XP10000 - Disk Array 36 pages. Cache lun xp
Également pour HP StorageWorks XP10000 - Disk Array : Note de mise à jour (13 pages), Manuel de l'administrateur (50 pages), Manuel de configuration (42 pages), Manuel de configuration (40 pages), Manuel de configuration (40 pages), Manuel de configuration (36 pages), Manuel de configuration (30 pages), Manuel de configuration (36 pages), Note de mise à jour (5 pages), Manuel de configuration du système (49 pages), Manuel de configuration du système (43 pages), Manuel de configuration du système (42 pages), Manuel de configuration du système (35 pages), Manuel de configuration (46 pages), Manuel de configuration (46 pages), Manuel de configuration (40 pages), Manuel de configuration (44 pages), Manuel de configuration (38 pages), Manuel de configuration (34 pages), Manuel de configuration (30 pages), Manuel de configuration (30 pages), Manuel de configuration (42 pages), Manuel de l'utilisateur (30 pages)

HP StorageWorks XP10000 - Disk Array Manuel de configuration

Fabric and connection parameter settings

Set each array port to FABRIC ON or OFF with connections of POINT-TO-POINT or FC-AL as shown
in the following table and figures. For detailed topology information, refer to the HP StorageWorks
SAN Design Reference Guide at:
http://www.hp.com/go/sandesign.
Figure 3 Point-to-point fabric topology example
.
Table 1 Fabric topology settings
Fabric parameter
OFF
ON
ON
OFF

Installing and configuring the host

This section explains how to install and configure Fibre Channel adapters (FCAs) that connect the
host to the disk array.

Loading the operating system and software

Follow the manufacturer's instructions to load the operating system and software onto the host. Load
all OS patches and configuration utilities supported by HP and the FCA manufacturer.

Installing and configuring the FCAs

Install and configure the Fibre Channel adapters using the FCA manufacturer's instructions.

Clustering and fabric zoning

If you plan to use clustering, install and configure the clustering software on the servers.
12
Installing and configuring VMware for the XP disk array
Connection parameter
FC-AL
Direct Fabric Attach
FC-AL
Direct Fabric Attach
Provides
NL-port (private arbitrated loop)
F-port (fabric port)
Not supported
Not supported