Également pour HP StorageWorks XP10000 - Disk Array : Note de mise à jour (13 pages), Manuel de l'administrateur (50 pages), Manuel de configuration (42 pages), Manuel de configuration (40 pages), Manuel de configuration (40 pages), Manuel de configuration (36 pages), Manuel de configuration (36 pages), Manuel de configuration (30 pages), Manuel de configuration (36 pages), Note de mise à jour (5 pages), Manuel de configuration du système (43 pages), Manuel de configuration du système (42 pages), Manuel de configuration du système (35 pages), Manuel de configuration (46 pages), Manuel de configuration (46 pages), Manuel de configuration (40 pages), Manuel de configuration (44 pages), Manuel de configuration (38 pages), Manuel de configuration (34 pages), Manuel de configuration (30 pages), Manuel de configuration (30 pages), Manuel de configuration (42 pages), Manuel de l'utilisateur (30 pages)

HP StorageWorks XP10000 - Disk Array Manuel de configuration du système

Fibre Address

In fabric environments, the port addresses are assigned automatically. In arbitrated
loop environments, set the port addresses by selecting a unique arbitrated loop
physical address (AL-PA) or loop ID for each port. For specific values, refer to the HP
StorageWorks LUN Configuration and Security Manager XP User Guide applicable
to your array.

Fabric and connection parameter settings

When configuring the disk array, use LUN Manager in Remote Web Console XP,
Command View XP, or Command View XP Advanced Edition to specify whether the hosts
and the disk array are connected by a fabric switch. Also, you must specify FC-AL or
point-to-point in the "Mode" field of the Change Port Mode pane. The default is FC-AL.
If you are using a fabric switch, consult the switch's documentation to determine whether
FC-AL or point-to-point should be used. Some fabric switches require that you specify
point-to-point to get the system running.
For detailed topology information, refer to the HP StorageWorks SAN Design Reference
Guide on the
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
www.hp.com
15