Également pour HP StorageWorks XP10000 - Disk Array : Note de mise à jour (13 pages), Manuel de l'administrateur (50 pages), Manuel de configuration (42 pages), Manuel de configuration (40 pages), Manuel de configuration (40 pages), Manuel de configuration (36 pages), Manuel de configuration (36 pages), Manuel de configuration (30 pages), Manuel de configuration (36 pages), Note de mise à jour (5 pages), Manuel de configuration du système (43 pages), Manuel de configuration du système (42 pages), Manuel de configuration du système (35 pages), Manuel de configuration (46 pages), Manuel de configuration (46 pages), Manuel de configuration (40 pages), Manuel de configuration (44 pages), Manuel de configuration (38 pages), Manuel de configuration (34 pages), Manuel de configuration (30 pages), Manuel de configuration (30 pages), Manuel de configuration (42 pages), Manuel de l'utilisateur (30 pages)

HP StorageWorks XP10000 - Disk Array Manuel de configuration du système
Example
3.
Record the device number for each new device on the worksheet in Appendix A,
Path
Worksheet. This information will be useful later during disk partitioning and
volume creation.
4.
Verify that all new disk devices are listed.
Configure disk devices
Configure the disks in the disk array using the same procedure for configuring any new
disk on the host. This includes the following procedures:

1. Creating the disk partitions

2. Assigning the new devices to volumes
3. Mounting the new volumes
4. Verifying client operations
Creating scripts to configure all devices at once may save you considerable time.
Creating the disk partitions
Before you create the disk partitions, consult the Novell documentation for confirmation
about the type of partition that is available with your operating system version.
NetWare 5.x
1.
At the server console enter LOAD INSTALL to load the Installation Option module.
2.
On the Installation Option screen, click Standard disk options and press ENTER to
access the NetWare disk options.
3.
On the Available Disk Options screen, select Modify disk partitions and Hot Fix
and press ENTER.
4.
The Available Disk Drives screen lists the devices by device number. Record the
device numbers. On the Available Disk Drives screen, select the device to be
partitioned and press ENTER.
5.
If the partition table has already been initialized, skip this step. If the partition table
has not yet been initialized, the partition table message is displayed. Press ENTER to
confirm the message. When the "Initialize the partition table?" message appears,
select Yes and press ENTER to initialize the partition table.
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
NetWare prompt>
1. 0x000B: [V6E0-A2-D7D:0] HP OPEN-3 rev:0111
2. 0x000C: [V6E0-A2-D7D:1] HP OPEN-3 rev:0111
:
:
LIST DEVICES
21