Également pour HP StorageWorks XP10000 - Disk Array : Note de mise à jour (13 pages), Manuel de l'administrateur (50 pages), Manuel de configuration (42 pages), Manuel de configuration (40 pages), Manuel de configuration (40 pages), Manuel de configuration (36 pages), Manuel de configuration (36 pages), Manuel de configuration (30 pages), Manuel de configuration (36 pages), Note de mise à jour (5 pages), Manuel de configuration du système (49 pages), Manuel de configuration du système (43 pages), Manuel de configuration du système (42 pages), Manuel de configuration du système (35 pages), Manuel de configuration (46 pages), Manuel de configuration (46 pages), Manuel de configuration (40 pages), Manuel de configuration (44 pages), Manuel de configuration (38 pages), Manuel de configuration (34 pages), Manuel de configuration (30 pages), Manuel de configuration (30 pages), Manuel de l'utilisateur (30 pages)

HP StorageWorks XP10000 - Disk Array Manuel de configuration
3.
In the right pane locate the DWORD entry "TimeOutValue." and right click. Select Modify, then
set the data value to x03c (hexadecimal) or 60 (decimal).
NOTE:
If the DWORD "TimeOutValue" doesn't exist, click Edit > New> DWORD value and enter
the name "TimeOutValue."

Sharing LUNs

To share LUNs between VMs within a single ESX server, set the SCSI controller to virtual mode. To
share LUNs across multiple ESX servers or in a virtual to physical configuration, set the SCSI controller
to physical mode.
VMware ESX Server 2.5x
1.
In the management interface, double-click the VM you plan to edit.
2.
Click the Hardware tab, select the SCSI controller you will use for your shared LUNs, and then
click Edit....
20
Installing and configuring VMware for the XP disk array