HP StorageWorks XP12000 Manuel de configuration du système - Page 34

Parcourez en ligne ou téléchargez le pdf Manuel de configuration du système pour {nom_de_la_catégorie} HP StorageWorks XP12000. HP StorageWorks XP12000 49 pages. Cache lun xp
Également pour HP StorageWorks XP12000 : Note de mise à jour (13 pages), Manuel de l'administrateur (50 pages), Manuel de configuration (42 pages), Manuel de configuration (40 pages), Manuel de configuration (40 pages), Manuel de configuration (36 pages), Manuel de configuration (36 pages), Manuel de configuration (30 pages), Manuel de configuration (36 pages), Note de mise à jour (5 pages), Manuel de configuration du système (43 pages), Manuel de configuration du système (42 pages), Manuel de configuration du système (35 pages), Manuel de configuration (46 pages), Manuel de configuration (46 pages), Manuel de configuration (40 pages), Manuel de configuration (44 pages), Manuel de configuration (38 pages), Manuel de configuration (34 pages), Manuel de configuration (30 pages), Manuel de configuration (30 pages), Manuel de configuration (42 pages), Manuel de configuration (50 pages), Manuel de l'utilisateur (30 pages)

HP StorageWorks XP12000 Manuel de configuration du système
Error Condition
The host does not reboot properly after hard
shutdown.
Physical volumes cannot be created.
Logical volumes cannot be created.
A file system is not mounted after rebooting.
The disk array performs a self reboot
because the disk array was busy or it
logged a panic message.
The disk array responds "Not Ready" or the
disk array has displayed "Not Ready" and
timed out.
The host detects a parity error.
The host hangs or devices are declared and
the host hangs.
34
Troubleshooting
Recommended Action
If you power off the host without executing
the shutdown process, wait three minutes
to allow the disk array's internal timeout
process to purge queued commands. If
the host restarts while the disk array is
processing queued commands, the host may
not reboot successfully.
Verify that the disk array logical devices are
correctly formatted.
Verify that the volume capacity for OPEN-x
volumes is not greater than the maximum
capacity allowed. See the
specifications
table.
Verify that the capacity of the volume group
is not less than the total capacity of the
partitioned logical volume.
Verify that the host was restarted correctly.
Verify that the file system attributes are
correct.
Reboot the host.
Contact HP.
Check the HBA and make sure it was
installed properly.
Reboot the host.
Make sure there are no duplicate disk array
TIDs and that disk array TIDs do not conflict
with any host TIDs.
Verify server hardware configuration.
Ethernet card may need to be in slot 9 for
NetWare to function with the HP Netserver.
Avoid shared interrupts; if unavoidable,
use sharing among similar card types.
Check for the latest device drivers and try
simplifying the configuration.
Emulation