Également pour HP XP20000/XP24000 : Note de mise à jour (13 pages), Note de mise à jour (4 pages), Manuel de l'administrateur (50 pages), Manuel de configuration (42 pages), Manuel de configuration (40 pages), Manuel de configuration (40 pages), Manuel de configuration (36 pages), Manuel de configuration (36 pages), Manuel de configuration (30 pages), Manuel de configuration (36 pages), Note de mise à jour (5 pages), Manuel de configuration (46 pages), Manuel de configuration (46 pages), Manuel de référence (46 pages), Manuel de configuration (40 pages), Manuel de configuration (44 pages), Manuel de configuration (38 pages), Manuel de configuration (34 pages), Manuel de configuration (30 pages), Manuel de configuration (30 pages)

HP XP20000/XP24000 Manuel d'intégration
EMCLI Installed Path – (required) specifies the location of the installation path for the
Enterprise Manager Command Line Interface. You need to configure Enterprise Manager
Command Line Interface with Oracle Management Server (OMS) as a prerequisite step
(see
The following plug-in instance properties are required for performance monitoring reports.
If you are not using performance monitoring reports, you can enter these values later.
4.
Click OK. A new target is added and appears in the agent's monitored targets list.

Removing the plug-in

To remove the plug-in, you must undeploy it. To undeploy the plug-in:
1.
Select HP StorageWorks P9000 Disk Array plug-in in management plug-in list and then click
the Undeploy icon.
2.
Follow the steps provided by Enterprise Manager.
10
Installation and removal
"Prerequisites" (page
6)).
Array Serial No – specifies the serial number of the disk array that contains LUNs
for performance monitoring.
LUNs for Performance Monitoring – specifies the LUNs to be monitored for
performance. The format is:
CU:LDEV.
Use a comma to list multiple LUNs:
15:08,15:09,15:0c,01:59,01:5a
DB Instance for Performance Monitoring – specifies the database to be monitored
for performance. Enter the database instance names. Use a comma to list multiple
database names:
db1,db2,db3
NOTE:
The Enterprise Manager Command Line Interface path field is mandatory
to successfully deploy the plug-in. However, the Array Serial No, LUNs for
Performance Monitoring, and DB Instance for Performance Monitoring properties
can be entered at a later time by clicking Monitoring Configuration in the plug-in
home page.