Également pour HP XP20000/XP24000 : Note de mise à jour (13 pages), Manuel d'intégration (29 pages), Note de mise à jour (4 pages), Manuel de l'administrateur (50 pages), Manuel de configuration (42 pages), Manuel de configuration (40 pages), Manuel de configuration (40 pages), Manuel de configuration (36 pages), Manuel de configuration (30 pages), Manuel de configuration (36 pages), Note de mise à jour (5 pages), Manuel de configuration (46 pages), Manuel de configuration (46 pages), Manuel de référence (46 pages), Manuel de configuration (40 pages), Manuel de configuration (44 pages), Manuel de configuration (38 pages), Manuel de configuration (34 pages), Manuel de configuration (30 pages), Manuel de configuration (30 pages)

HP XP20000/XP24000 Manuel de configuration
Creating storage groups
Mapping volumes and WWN/host access permissions to the storage groups
For details see the HP StorageWorks XP LUN Manager User s Guide or the HP StorageWorks XP
Command View Advanced Edition Software Device Manager Web Client User s Guide. Note the
LUNs and their ports, WWNs, nicknames, and LDEVs for later use in verifying host and device
configuration.

Setting up Virtual Machines (VMs) and guest operating systems

Setting the SCSI disk timeout value for Windows VMs

To ensure Windows VM's (Windows 2000 and Windows Server 2003) wait at least 60 seconds for
delayed disk operations to complete before generating errors, you must set the SCSI disk timeout
value to 60 seconds by editing the registry of the guest operating system as follows:
CAUTION:
Before making any changes to the registry file, make a back up copy of the existing file.
1.
Start the registry editor: select Start > Run, enter regedit.exe, and click OK.
2.
In the directory tree in the left panel, select HKEY_LOCAL_MACHINE > System > CurrentControlSet
> Services > Disk.
3.
In the right pane locate the DWORD entry "TimeOutValue." and right click. Select Modify, then
set the data value to x03c (hexadecimal) or 60 (decimal).
NOTE:
If the DWORD "TimeOutValue" doesn't exist, click Edit > New> DWORD value and enter
the name "TimeOutValue."

Sharing LUNs

To share LUNs between VMs within a single ESX server, set the SCSI controller to virtual mode. To
share LUNs across multiple ESX servers or in a virtual to physical configuration, set the SCSI controller
to physical mode.
16
Installing and configuring VMware for the XP disk array