Care and Replacement
Removing and replacing the lamp unit
J
1.
Use a Phillips screwdriver to loosen the 3 lamp
unit fixing screws until the screws turn freely.
Lamp unit
fixing screws
Lamp unit lock
2.
Hold the handle of the lamp unit and release the
lamp unit lock in the direction of an arrow.
3.
Pull out the lamp unit gently from the projector.
Attaching the top cover
J
1.
Attach the hinge parts of the top cover to the
projector and press slightly until it clicks.
When the projector is mounted on the ceiling,
attaching the hinge parts is not required.
2.
Hook the top cover safety hook to the projector.
3.
Hook the tabs of the top cover to the front of the
projector body and lower slowly.
4.
Press the back corner of the top cover gently until
it clicks.
Make sure to hook the top cover safety hook to the
body.
NOTE:
•
Be sure to install the lamp unit and the top cover of the projector securely. If they are not
securely installed, it may cause the protection circuit to operate so that the power cannot be
turned on.
•
Grip the handle and keep the lamp unit paralleled when you remove the lamp unit.
•
Do not switch the power on while the top cover is opened.
•
When the projector is mounted on the ceiling, keep the lamp unit paralleled up and remove.
Resetting the
J
If the lamp usage time has passed 2 000 hours (when LAMP POWER has been set to NORMAL), the
projector will switch to standby mode after approximately 10 minutes of operation. The resetting procedure
should thus be completed within 10 minutes.
1.
Connect the power cord to the projector and a wall
outlet, and switch MAIN POWER on.
2.
Switch the power button.
3.
Press the
MENU button to display the menu.
4.
Press ▲ ▼ to select
ENTER button.
5.
Press ▲ ▼ to select
HIGH ALTITUDE MODE
LAMP POWER
VIERA LINK SETTINGS
TEST PATTERN
LAMP RUNTIME
E
28 -
NGLISH
LAMP RUNTIME
OPTION and press the
LAMP RUNTIME.
OFF
NORMAL
1820H
4.
Replace the new lamp unit while making sure that
the direction of insertion is correct.
Press the top of the lamp unit downwards and make
sure the unit is installed securely.
Press down here
5.
Tighten the lamp unit fixing screws securely with a
Phillips screwdriver.
Top cover safety hook
6.
Press and hold the
ENTER button for
approximately 3 seconds.
7.
The confirmation screen will be displayed and
select OK.
8.
Switch off the power button to reset the duration of
the LAMP RUNTIME.
9.
Confirm the duration of time in
reset to "0".
Press down here
Tabs
LAMP RUNTIME is