Using Web Browser (continued)
Error information page
If [Error (Detail)] is displayed in the self-diagnosis information display column on the [Projector status] screen, click
the part to display the details of the error.
・
Depending on the nature of the error, the projector may be placed in the standby mode for its own protection.
■
When [FAILED] has appeared for an item
Parameter
MAIN CPU BUS
FAN
INTAKE AIR TEMPERATURE
OPTICS MODULE TEMPERATURE
AROUND LAMP TEMPERATURE
LAMP REMAIN TIME
LAMP STATUS
AIR FILTER
INTAKE AIR TEMP.SENSOR
OPTICS MODULE TEMP. SENSOR
AROUND LAMP TEMP. SENSOR
BATTERY
AIRFLOW SENSOR
COLOR WHEEL
The ACCESS ERROR INFORMATION/ACCESS INFORMATION displays the past several thousand accesses/
requests. If many accesses/requests are made at a time, some of them may not be found in the information.
Check the ACCESS ERROR INFORMATION/ACCESS INFORMATION regularly.
Trouble has occurred in the microcomputer circuitry. Consult your dealer.
Trouble has occurred in the fan or its drive circuit. Consult your dealer.
The intake air temperature is too high. It may be that the projector is being used in an
operating environment where the temperature is high such as near a heating appliance.
The temperature inside the projector is high. It may be that the projector is being used
in an operating environment where the temperature is high such as near a heating
appliance.
The temperature around the lamp is too high. It may be that the projector's ventilation
holes are blocked.
The lamp runtime has exceeded the prescribed cumulative time, and it is now time to
replace the lamp.
The lamp has failed to light.
Wait a short while for the lamp to cool off, and then turn on the power.
Trouble has occurred in the AIR FILTER. Consult your dealer.
Trouble has occurred in the sensor used to detect the intake air temperature.
Consult your dealer.
Trouble has occurred in the temperature detection sensor inside the projector.
Consult your dealer.
Trouble has occurred in the sensor used to detect the exhaust air temperature.
Consult your dealer.
The backup battery has been run out. Consult your dealer.
Trouble has occurred in the sensor used to detect the airflow volume.
Consult your dealer.
Trouble has occurred in the sensor used to detect the COLOR WHEEL.
Consult your dealer.
23
OK:
Normal operation
FAILED:Occurrence of trouble
Description