HTC 650 HDX Manuel - Page 34

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} HTC 650 HDX. HTC 650 HDX 40 pages.
Également pour HTC 650 HDX : Manuel de l'utilisateur (48 pages)

HTC 650 HDX Manuel
Electronic error codes
Error
Cause
code
E13
Anti-restart switch tripped
E14
Earth fault
E15
Excess voltage
E21
Excess temperature
E22
Internal processor error
E30
Internal communications error
6.3.2

Resetting the frequency converter

Press and hold the "RESET" button in for two seconds.
6.3.3

Checking the last error code

1.
Press the "Set key" button, D001 is shown in the display.
2.
Press the "arrow up" button, until D081 is shown in the display.
3.
Press the "Set key" button, the error code is shown in the display.
4.
Press the "arrow up" button, the frequency at the time of the error is shown in the
display.
5.
Press the "arrow up" button, the motor current during the error is shown in the
display.
6.
Press the "arrow up" button, the voltage of the DC bus during the error is shown in
the display.
7.
Press the "arrow up" button, the operating time accumulated up to the time of the
error is shown in the display.
8.
Press the "arrow up" button, the time accumulated with the voltage connected up to
the time of the error is shown in the display.
Figure  6-1. "Set key" button
28
Action
Check the operation when starting the machine, see Starting the
machine, page 22.
Check the motor's cables and connections.
Mains voltage too high or disturbance in the mains supply.
Check the supply voltage, change socket.
See E08.
Contact HTC Service Centre.
Contact HTC Service Centre.
HTC 650 HDX
3.0