EasyPro Stratus SRC50K Instructions - Page 2

Parcourez en ligne ou téléchargez le pdf Instructions pour {nom_de_la_catégorie} EasyPro Stratus SRC50K. EasyPro Stratus SRC50K 2 pages. Repair kit

7.
Press retainer plate with piston cup into cyl-
inder all the way to the piston. The cylinder
can be rotated to align the screw holes. Ap-
ply thread locking compound (Loctite
to retainer screws, torque screws to 10-13
inch-pounds.
10.
Check that orientation of the valve plate(s)
with ports is correct and place over
cylinders.
Check that all external accessories such as relief valves and gauges are not damaged before re-operating product.
(800) 448-3873 • Grant, MI 49327 • www.easypropondproducts.com
Stratus SRC Series Repair Kit Instructions
8.
Remove the cylinder o-ring(s) from the bot-
tom of valve plate(s) and install new o-rings.
222)
®
11.
Remove old and install new head o-rings in
the o-ring grooves on top of valve plate
Visit easypropondproducts.com/resources for more information
9.
Inspect the leaf valves for damage or wear.
NOTE: There is one intentionally "bent"
leaf valve per set. If leaf valves need to be
replaced, a complete leaf valve plate can be
ordered. The screws holding the leaf valves
are susceptible to breaking which makes in-
dividual leaf valve replacement very difficult.
12.
Reinstall head over valve plate(s) checking
that orientation with ports is correct. Torque
screws to 50 inch-pounds
Unit must be unplugged
before servicing
9156 - 5/17