Bionaire BAP412 - 2 Manuel d'instruction - Page 2
Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} Bionaire BAP412 - 2. Bionaire BAP412 - 2 2 pages.
Également pour Bionaire BAP412 - 2 : Manuel d'instruction (19 pages)

BAP412IUK06EM1.qxd
6/19/06
16:44
Page 4
HOW THE AIR PURIFIER WORKS
U.K. and IRELAND
Dirty, dust laden air is drawn through the back of
the air purifier and through the multi-stage filtration
PLEASE READ AND SAVE THESE
system.
IMPORTANT INSTRUCTIONS.
1. The carbon filter will help clear odours making
the air cleaner and fresher.
With proper care and use, this Bionaire
®
air purifier will give you fresh, clean air
2. The HEPA filter entraps 99% of all smaller visible
for many years.
and non-visible particles down to 2 microns in
size.
NOTE: Before reading these instructions, please
view the corresponding illustrations.
PRODUCT FEATURES
SAFETY PRECAUTION
Ioniser
Carefully read and retain all instructions before
Your Bionaire
®
using the air purifier.
controlled ioniser, which when turned on, releases
negative ions into the outgoing filtered air. Ions
• To avoid fire or shock hazard, check that the
are tiny particles that carry either a positive or
voltage on the product corresponds to your
electricity supply and plug directly into an
negative charge. These ions exist naturally all
around us in the air, water and ground. Both positive
electrical outlet.
and negative ions are colourless, odourless and
• To avoid fire hazard, never put the cord under
completely harmless.
rugs, or near any heat source.
Negative ions help the air purification process by
• Carefully discard any plastic wrapping that was
attaching themselves to very small airborne particles
used for the packaging.
in the room. These particles take on a negative
• Do not use the air purifier outside.
charge and may join with positively charged particles,
• Do not place the unit near any heat source or
such as dust, pollen, smoke and pet dander to form
in direct sunlight.
larger particles that are then more readily captured
• Always unplug the air purifier before removing
by the filter system, or they may be attracted to
the grill, changing the filters, cleaning the air
positively charged surfaces like walls or floors.
purifier or whenever it is not in use.
You may also note, after extended use, that dust
• Do not use in or around water or any other liquids.
may have collected around the grills or front panel.
Do not attempt to wash the unit under running
This is from the ionisation effect caused by the
water.
negative ions exiting from the air outlet.This dust
• Use appliance only for intended household use
does not come from the air output, but is drawn
as described in this manual.
out of the uncleaned air going past the air outlet.
• Ensure that all air openings are not restricted
This is additional evidence of the air cleaning
or covered in any way.
effectiveness of negative ions. The dust can be
• Do not place anything on top of the unit.
easily removed with a clean, dampened cloth or
soft brush.
• Never insert any object into any openings.
NOTE: it is important to change the HEPA filter
• Do not use the air purifier if any part is missing
at recommended intervals. Using the ioniser in
or damaged in any way.
conjunction with dirty filters may result in dirty
• Do not attempt to repair or adjust any mechanical
particles exiting the air purifier and being attracted
functions of this unit. If the unit becomes damaged
to walls, carpets, furniture and other household
return to the place of purchase or phone the
objects. These dirty particles may prove very difficult
helpline number on the back of this leaflet.
to remove.
• If the supply cord or plug is damaged, it must
be replaced by the manufacturer or its service
PRE-OPERATING INSTRUCTIONS
agent or a similarly qualified person in order to
1. After removing the unit from the box, remove
avoid hazard.
the plastic covering from the unit.
• The air purifier contains no user serviceable
2. Select a firm level place where there are no
parts and should the product suffer damage or
obstructions to the air inlet (front grill) or filtered
breakdown it must be returned to the manufacturer
air outlet.
or its service agent.
3. Remove the inlet grill by pulling the grill towards
• Should the air purifier stop working, first check
you.
the fuse in the plug (UK only) or fuse/circuit breaker
4. Remove both HEPA filters by gripping on both
at the distribution board is operating, before
sides and pulling forward.
contacting the manufacturer or service agent.
5. Remove protective plastic bag from each filter
cartridge. The filter clip can only be attached
to the hang tabs on the filter one way (see
Figure 3). The filter clip should easily slide
onto the filter hang tabs. Do not use force
whilst attaching the filter clip to the filter. Align the
clip on the HEPA filter with the rails on the inside
of the unit (see Figure 4).
NOTE: The pleated material and rubber gasket
should be facing towards the unit when applied.
6. Replace the inlet grill by sliding back on to the
unit. Make sure that it snaps securely into position
(the grill only goes on one way).
NOTE: Do not point outlet towards wall.
Air Purifier has an independently
OPERATING INSTRUCTIONS
1. Plug into a suitable electrical outlet.
2. Select the required operating Speed: Hi (
Medium (
), Low (
to the appropriate setting.
3. To release negative ions into the filtered air,
slide the Ioniser button (
light will illuminate.
4. The ioniser will not work unless the unit is running.
5. For optimum air filtration, it is recommended to
operate the air purifier continuously. Its rugged
motor is designed to give many years of service.
6. For continuous use, it is recommended to
operate the air purifier at the Medium (
setting. For quieter operation or use in a
bedroom, select the Low (
high levels of air pollution are present, select
the Hi (
) setting to quickly circulate clean
filtered air.
CLEANING AND MAINTENANCE
1. Turn the air purifier off and unplug it before cleaning.
2. The outside of the air purifier can be cleaned
with a soft, clean dampened cloth.
3. The filtered air outlet can be cleaned of dust
with a small, soft brush.
4. If you wish to clean the inside of the air purifier,
please only use a dry, soft cloth to wipe it down.
FILTER REPLACEMENT
IMPORTANT: IN ORDER TO RETAIN THE
EFFICIENCY OF YOUR AIR PURIFIER, THE
HEPA FILTER NEEDS TO BE CHANGED EVERY
6 MONTHS.
NOTE: Your air purifier has a filter condition sticker
that servers as a colour coded reference point.
1. Every few weeks check the condition of the
pre-filter.
2. Remove the inlet grill. If the foam pre-filter has
collected a noticeable amount of dust, remove
it from the inlet of the grill and wash it in warm
soapy water. Rinse and dry the pre-filter thoroughly
before replacing it in the inlet of the grill.
3. With the inlet grill removed, remove the HEPA
cartridge and dispose in the dustbin. DO NOT
try to wash and re-use the HEPA filter. Replace
with a new HEPA filter-BAPF30 removing the
protective plastic bag before inserting into the
air purifier.
4. Align the clips on the side of your HEPA filter with
the rails on the inside of the unit. Gently slide
the filter onto the rails.
5. The filter clip should easily slide onto the filter
hang tabs. Do not use force while attaching the
filter clip to the filter. Align the clip on the side of
your HEPA filter with the rails on the inside of
the unit.
NOTE: The pleated material and rubber gasket
should be facing towards the unit when applied.
),
6. Replace the inlet grill by sliding back on to the
) by sliding the switch
unit. Make sure that it snaps securely into position
(the grill only goes on one way).
NOTE: Do not point outlet towards wall.
) to ON. The amber
REPLACEMENT FILTER
BAPF30 HEPA Filter (usage 1 pc)
The manufacturer reserves the right to change
or modify any specifications without notice.
TROUBLESHOOTING
)
Problem
Solution
) setting. When
Unit will not operate. Check to make sure the unit
is plugged in.
Check to make sure the unit
is on by turning the knob.
Make sure the filters are
properly installed and firmly
close the door.
Decreased airflow.
If the filters have not been
changed for 6 month or more,
change the HEPA filters.
Check to ensure nothing is
blocking the air inlet and
filtered air outlet.
BAP412
Figure 1
Figure 2
A
B
D
C
A. Inlet Grill
B. Washable Foam Pre-Filter
C. HEPA/Carbon Filter
D. Filtered Air Outlet
E. Ioniser Light
F. Ioniser Control
G. Speed Control
Figure 4
Figure 3
E
F
G