Initial Set-Up:
1. Diagnostic Test: Press Enter, 2, 6, Play/Pause phone will play back (5) Beeps (1st Beep=External Power Supply; 2nd
Beep=LED; 3rd Beep=Microphone; 4th Beep=Speaker; 5th Beep=Backup Battery). If any item fails during test you will hear
a Blat not a Beep. If you hear a Blat, contact Alpha Communications® Technical Support.
Note: If you receive a Blat for the LED, check the LED operation to be sure it is not working before contacting Alpha® Technical Support.
2. Connect to standard RJ11 phone jack. If splicing connection, only hook up Red and Green Wires from the phone cable. If
connecting to a SmartRescue unit, you must connect all four wires (check for 24vdc or 48vdc supply at the splice).
Troubleshooting:
1. If the phone dials only one digit and hangs up, there is another Auto-Dialer on the line. You need to re-wire the system so
that the Alpha Refuge unit is either in parallel or ahead of it.
2. If the phone dials a couple of digits and gets a busy signal, the unit is installed on a switchboard line and needs to be
programmed to dial the appropriate access code to get an outside line (usually an 8 or 9).
3. If the phone does not respond, make sure the green LED (D1) on the circuit board is lit. If not, check to be sure the power is
properly connected.
4. If the phone is making phantom calls, it is installed on a Ring Down Line. You must turn off the "Telephone Line Check"
feature (see Optional Programming Instructions).
Wiring Diagrams: 12vac/dc Models:
Direct 12vac/dc Powered
*
Bat
12vac/dc
To 12vac/dc
Power Supply
Note: If Elevator Communications Failure is
required, connect to our Alarm Relay.
To Phone Line:
Enter
Requires a twisted
Record
shielded pair.
When used with
Play/Pause
AlphaRefuge,
requires two
Stop
twisted shielded
+ -
pairs.
MIC Speaker
42 Central Drive • Farmingdale NY 11735-1202
800-666-4800 • www.alphacommunications.com
120vac to 12vac/dc Powered
*
Bat
12v
Transformer
*
Troubleshooting & Diagrams
RCB2100 Series Call Boxes
To Phone Line:
Enter
Requires a twisted
Record
shielded pair.
When used with
Play/Pause
AlphaRefuge,
requires two
Stop
twisted shielded
+ -
pairs.
MIC Speaker
White/Neutral
To 120vac
Black/Hot
AWD179
01/2024