holes in the flexible pipe and install sheet metal screws to secure.
DIRECT VENT FITTING
Combustion Gases
Outside Air for Combustion
Deck
GAS SUPPLY AND HOOK-UP
THE HEATER OPERATES ONLY ON LOW PRESSURE LPG GAS (11"w/c)
If there is a propane fuel system installed a separate supply line must be supplied for the heater.
This line must be equipped with a low-pressure regulator (Dickinson Part No. 19-151)
Connect to the 3/8" flare connector of the heater with copper or an approved hose. During this
procedure some particles may get into the fuel line. These could block or restrict the small heater
orifice. BLOW OUT FUEL LINE PRIOR TO ATTACHING TO THE PROPANE SUPPLY AND
THE HEATER.
Disposable Propane Bottle
It is necessary to install a pressure regulator for gas supplied from a propane bottle.
For this
type of installation we suggest using a Dickinson Low Pressure Kit (Part No. 19-150) This Kit
includes a pressure regulator (11 ins W/C) and a mounting kit. The kit must be mounted
outside.
A Dickinson AGA/CGA propane hose can be used to connect this Kit to the heater.
These are available in 10 ft ( 3m) (Part No. 19-100-10) or 20 ft (6m)(Part No. 19-100-20)
AFTER GAS HOOK-UP AND BEFORE LIGHTING THE HEATER
TEST ALL GAS AND CONNECTIONS FOR LEAKS WITH A
SOAP SOLUTION