Mounting Accessories

General
The accumulators should be properly fitted / clamped on the system. Clamping should not cause the shell or the
accumulator connection to be stressed due to over tightening. It is necessary, especially with larger capacities / lengths,
horizontal mounting or with heavy units, to use fasteners (clamps, brackets etc) that support the accumulator and prevent
dangerous vibrations.
To achieve a high degree of efficiency, the accumulator should be fitted as close as possible to the installation it serves. The
space necessary for charging & gauging kit is atleast 150mm above the gas fill valve.
Position
It is suggested that the accumulators are installed vertically with gas side on top. The manufacturers name plate stating
the initial pressure must be visible. Moreover access to the vent screw, if any, must be kept unobstructed.
The mounting must be such that, should a rupture occur on the pipe system at the liquid connection, or should the gas fill
valve break, the accumulator cannot be pulled from its mounting by the forces involved. No welding or other mechanical
process must be carried out on the accumulator shell for the purpose of attaching fasteners.
6