Epever LS EPD Series Manuel de démarrage rapide
Parcourez en ligne ou téléchargez le pdf Manuel de démarrage rapide pour {nom_de_la_catégorie} Epever LS EPD Series. Epever LS EPD Series 2 pages. Solar charge controller
HUIZHOU EPEVER TECHNOLOGY CO., LTD.
Solar Charge Controller
General Information
1.
LS EPD series solar charge controller adopts the most advanced digital technique and
operates fully automatically. It is ideal for extreme environments with corrosion, dust, water,
etc., and has various unique functions:
Electronic protection: Over charging, over-discharging, overload, short circuit, and reverse
protection of solar module
High efficient Series PWM charging increases the battery lifetime and improves the solar
system performance
Widely used, automatically recognizes day/night
Battery LED to indicate battery status
Industrial design, the wide application range
Digital tube menu, only one key solve all setting simply
Intelligent timer function with 1~13 hours option
IP67 protection
2. Features and Mounting
2
1
3
4
5
6
7
8
Do not install this product in humid, salt spray, corrosion, greasy, flammable,
explosive, dust accumulative, or other severe environments.
①
Charging Status LED indicator
②
Battery Status LED indicator
③
Temperature Sensor
④
Solar Module Terminals
9 10
⑥
Load Terminals
⑦
Digital tube
⑧
Key
⑨
Aluminum housing
1
Tel: +86-752-3889706
⑤
Battery Terminals
1) Connect components to the charge controller in the sequence "①Battery > ②Load >
Mounting
③PV" and pay much attention to the "+" and "-." Always power the battery first.
2) Check whether the battery indicator is green after powering the battery. If it's not green,
please refer to chapter 4.
3) The fast-acting fuse should be installed as close to the battery. The suggested distance is
within 150mm.
3. Indicators Description and Operation
1) Indicator Status Description
Charging Status
Green
LED indicator
Green
Green
Green
Battery Status LED
indicator
Orange
Red
Red
Radix Point of Digital
tube
Red
(Load indicator)
Red
2) Operation
The digital tube displays the load work mode; please refer to the
correspondence table of Load Work Mode & LED digital tube value.
Pressing the key to configure the parameter, refer to the below
configuration method:
Digital tube Key
1) After Powering on, disconnect the PV or connect the PV (Voltage<5V), and the light of
the digital tube point goes on; Connect the PV (Voltage>6V), and the light of the digital
tube point goes off.
2) The key can be used to operate switching on/off the load (Manual control) or clearing
the faults
3) Press the button over 5S to light the digital tube and enter the parameter browsing
mode. End-users can cycle browse the parameter by clicking the button.
4) After the digital tube displays the value to be configured, release the key and wait for
15S. The Digital Tube stops flashing; the configuration is successful.
Website: www.epever.com
Mounting hole Φ5
⑩
On Solid
Normal
Fast Flashing
Overvoltage
On Solid
Normal
Slowly Flashing
Full
On Solid
Under voltage
On Solid
Over discharged
On Solid
Load ON
Slowly Flashing
Over Load
Fast Flashing
Short Circuit
2