7.
FOLLOw THESE STEPS wHEN BATTERY IS OUTSIdE VEHICLE.
A SPARK NEAR THE BATTERY MAY CAUSE BATTERY EXPLOSION.
TO REdUCE RISK OF A SPARK NEAR BATTERY:
7.1
Check polarity of battery posts. POSITIVE (POS, P, +) battery post usually
has a larger diameter than NEGATIVE (NEG, N, –) post.
7.2
Attach at least a 24-inch-long 6-gauge (AWG) insulated battery cable to
NEGATIVE (NEG, N, –) battery post.
7.3
Connect POSITIVE (RED) charger clip to POSITIVE (POS, P, +) post of
battery.
7.4
Position yourself and free end of cable as far away from battery as pos-
sible – then connect NEGATIVE (BLACK) charger clip to free end of cable.
7.5
Do not face battery when making final connection.
7.6
When disconnecting charger, always do so in reverse sequence of con-
necting procedure and break first connection while as far away from bat-
tery as practical.
7.7
A marine (boat) battery must be removed and charged on shore. To
charge it onboard requires equipment specially designed for marine use.