Performance
problems
often result from little things that you can fix yourself.
Please
read through this chart for a possible solution
if a problem occurs.
PROBLEM
No ammeter reading.
Circuit breaker in
charger
cycles on
and off with a
clicking sound in the
MANUAL setting.
Ammeter
reads less
than selected
charge
rate when charging.
POSSIBLE
CAUSE
Clamps not making good
connection.
Ammeter needle
stays at the right
side of the meter.
2-amp charge rate.
No AC power reaching
charger.
Shorted battery clamps.
Shorted
battery.
Charger
leads reversed
on battery.
Extension cord too long
or gauge too small.
Battery has weak cell or
sulfated plate.
SOLUTION/REASON
Check for poor connection at battery.
Make
sure clamps and posts are clean.
Battery
may not accept
an AUTOMATIC
charge
if
severely
discharged.
Use MANUAL
setting,
see "Using Your Battery Charger" on page 6.
Ammeter
needle will indicate little activity at
the 2-amp charge rate.
Check AC outlet and extension
cords for
loose fitting plug.
Check for open fuse or circuit breaker
supplying AC outlet.
Separate the clamps. Circuit breaker cycles
when current draw is too high.
Check for wom cables and replace if
needed.
Have a Sears technician test the battery.
Correct
connections.
Use shorter or heavier extension
cord.
Sulfated battery will eventually
take a
normal charge if left connected.
If the
battery will not take a charge, have it
tested by a Sears technician.
Battery is partially
Continue charging
battery.
charged.
Charger makes a
Transformer laminations
Continue charging. Buzz is not abnormal.
loud buzz or hum.
vibrate
(buzz).
Battery severely
discharged.
: Battery size selector
switch in the wrong
position
Continue charging battery for another two
hours. If problem continues, consult a
qualified technician.
Make sure size selection is in proper 12 or
24 volt position.
If the above solutions do not eliminate the problem...call
toll-free
from anywhere
in the U.S.A, 1-800-SEARS-64
• (1-800-732-7764)
7 AM to 4:30 PM CST Monday through Friday