Diehl Metering Sharky 775 Instruction d'inspection et d'essai - Page 10

Parcourez en ligne ou téléchargez le pdf Instruction d'inspection et d'essai pour {nom_de_la_catégorie} Diehl Metering Sharky 775. Diehl Metering Sharky 775 18 pages. Ultrasonic energy meter

Energy test by test port

3.3.
The meter has an own test port. For this test it is not necessary to set the meter in the calibration
mode.
For this test is a special "energy- test- cable" available (code. no. 3024799)
The wires are defined as:
Pulse output:
Volume pulse input:
GND:
Note: The meter needs ~1min to activate the adapted cable
a. Input:
Volume pulses has to be time continuously
f
≤ 100 Hz
max
Passive Pulse:
R
≤ 10 kΩ (internal Pull-UP U
max
b. Output:
Energy pulses as burst
Pulse duration has a dynamic adaption on the frequency
f
≤ 800 Hz
max
U
. ≤ 60 V
max
I
. ≤ 20 mA
max
Pulse rates:
sizes qp
≤6
>6
>60
>600

Energy test and calibration by NOWA

3.4.
The meter test and calibration over NOWA is available
Industriestraße 13
91522 Ansbach
Deutschland
Tel. +49 981 18 06-015
www.diehl.com/metering
White
Green
Brown
high
Pulse value
Pulse value
volume input
energy output
1 l
10 Wh / kJ / Btu / kcal
10 l
100 Wh / kJ / Btu / kcal
100 l
1000 Wh / kJ / Btu / kcal
1000 l
10000 Wh / kJ / Btu / kcal
= 3 V)
Seite 10 von
18