Olympus Stylus 820 Manuel d'instruction - Page 4

Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} Olympus Stylus 820. Olympus Stylus 820 5 pages. Ikelite digital camera housing

O O p p t t i i o o n n a a l l A A c c c c e e s s s s o o r r i i e e s s C C o o n n t t i i n n u u e e d d
AF35 Autoflash kit
includes :
- AF35 strobe
- Flex arm
- AutoFlash sensor
- Handle with rubber grip
- Tray (single or dual)
- Mounting hardware
The Autoflash AF35 replicates your
camera's flash for automatic exposure in
any situation. Single or dual trays can
attach directly to your housing. The
exposure selector dial on the side of the
sensor provides fine tuning to optimize
results with a variety of digital still
cameras. Once you find an exposure level
that you like, leave the dial on that
number for automatic operation.
C C o o m m p p l l e e t t e e i i n n f f o o r r m m a a t t i i o o n n r r e e g g a a r r d d i i n n g g o o p p t t i i o o n n a a l l a a c c c c e e s s s s o o r r i i e e s s a a v v a a i i l l a a b b l l e e a a t t
w w w w w w . . i i k k e e l l i i t t e e . . c c o o m m
C C o o n n t t r r o o l l M M a a i i n n t t e e n n a a n n c c e e
Ikelite controls are designed to provide years of reliable service
with minimal maintenance.
1 . Push button controls require no maintenance other than rinsing
in fresh water after saltwater use. If a push button control
becomes difficult to push or if it sticks when depressed, soak the
housing in luke warm fresh water. After a few minutes operate
the push button. If this does not correct the problem, return the
housing to Ikelite for maintenance.
housing
2. Some of the controls have long shafts. These controls can be
pulled out, exposing the shaft (see drawing).
To lubricate the control, gently pull on the knob until the
stainless steel shaft is exposed. Lightly lubricate the shaft, then
move the shaft in and out several times. This will lubricate the
x-ring in the Ikelite control gland. This should be done before
using the housing after a prolonged storage period, or once a
week when the housing is in use.
13
lubricate shaft
pull out to
expose shaft
15
M M a a i i n n t t e e n n a a n n c c e e
The Ikelite Digital Housing should be given the same care and
attention as your other photographic equipment. In addition to
normal maintenance we recommend that the housing be returned
to Ikelite periodically to be checked and pressure tested.
1 . D D o o N N o o t t leave the camera and housing in direct sunlight for
prolonged periods. Heat may damage the camera.
2. D D o o N N o o t t ship the camera in the housing.
3. Before using the housing, always check the tightness of the s s e e t t
s s c c r r e e w w in each control knob.
Check each c c o o n n t t r r o o l l g g l l a a n n d d penetrating the housing to make sure
they are tight. There is a slight chance that either could vibrate
loose during travel.
4. Keep the back o-ring clean and lightly lubricated. To lubricate
remove the o-ring from the back. Put a small amount of lkelite
lubricant on your fingers. Draw the o-ring through your fingers
to apply a light coating of lubricant. Only apply enough
lubricant to make the o-ring feel slick. D D o o N N o o t t s s t t r r e e t t c c h h t t h h e e
o o - - r r i i n n g g . This light coating of lubricant will help to keep the
o-ring from drying out and will help to show a dark sealing
line when the housing back is properly sealed.
5. Keep the area where the o-ring fits and the sealing surface of
the housing clean.
6. Rinse the housing exterior thoroughly in fresh water after each
salt water use. Dry with a soft cloth. Dry lens port to eliminate
water spotting.
After several uses in salt water soak the housing exterior in a
mild soap solution, rinse and dry before storage. When storing
the housing, remove the back o-ring, lightly lubricate and place
in a plastic bag. Place the plastic bag with o-ring inside the
housing for safe keeping.
C C o o n n t t r r o o l l M M a a i i n n t t e e n n a a n n c c e e C C o o n n t t . .
3. Some of the controls have a short shaft and cannot be pulled
out exposing the shaft for lubrication. In the unlikely event one
of these controls sticks or becomes difficult to operate you can
remove the control from the housing and lubricate it, or return
the housing to Ikelite for maintenance. To remove the control,
loosen the set screw in the knob (allen wrench required);
remove the knob. If there is salt or dirt build-up on the exposed
control shaft, clean the shaft. Open the housing and gently slide
the control shaft out of the control gland. Clean and lightly
lubricate the shaft, including the end of the shaft. Slide the
shaft back into the control gland and gently slide it back and
forth a few times without fully removing the shaft from the
gland. Replace the knob, NOTE the flat area on the shaft, the
set screw in the knob should tighten down against the flat area
on the control so the knob does not turn on the shaft.
housing
control
shaft
Flat
Tighten set screw down
against this area when
replacing the knob.
Lubricate end of shaft
before reinserting into
gland
14
gland
Loosen set screw
(allen wrench required)
16