Olympus CX21LED Manuel d'instructions - Page 5

Parcourez en ligne ou téléchargez le pdf Manuel d'instructions pour {nom_de_la_catégorie} Olympus CX21LED. Olympus CX21LED 28 pages. Biological microscope

Olympus CX21LED Manuel d'instructions
1
Getting Ready
@
Fig. 1
2
Maintenance and Storage
1. To clean the lenses and other glass components, simply blow dirty away using a commercially available blower and wipe
gently using a piece of cleaning paper (or clean gauze).
If a lens is stained with fingerprints or oil smudges, wipe it gauze slightly moistened with commercially available absolute
alcohol.
Since the absolute alcohol is highly flammable, it must be handled carefully.
Be sure to keep it away from open flames or potential sources of electrical sparks –– for example, electrical
equipment that is being switched on or off, since such operation may cause ignition of a fire.
Also remember to always use it only in a well-ventilated room.
2. Do not attempt to use organic solvents to clean the microscope components other than the glass components. To clean
them, use a lint-free, soft cloth slightly moistened with a diluted neutral detergent.
3. Do not disassemble any part of the microscope as this could result in malfunction or reduced performance.
4. When not using the microscope, store it in a dry locker or cover it with a dust cover.
²
Fig. 2
1. A microscope is a precision instrument. Handle it with care and avoid
²
subjecting it to sudden or severe impact.
2. Do not use the microscope where it is subjected to direct sunlight,
high temperature and humidity, dust or vibrations. (For the operating
conditions, see chapter 7, "SPECIFICATIONS" on Page 15.)
3. Always use the tension adjustment ring to adjust the rotation tension of
the coarse adjustment knob.
4. Be sure to leave enough space around the AC adapter when installing
the microscope.
5. When carrying the microscope, first make sure that the AC adapter has
been disconnected and hold both sides around the hole of the arm as
shown in Fig. 1 and carry carefully.
# To prevent damage, do not hold the microscope by the stage 1 or
observation tube 2.
Be sure to remove the specimen; otherwise, it may fall.
5. To clean the condenser, fully loosen the securing knob 1, then remove
the condenser by lowering it with the condenser height adjustment knob
2, and wipe the front lens of the condenser.
The condenser can be attached by reversing the above removal
procedure.
@
6. When disposing of the microscope. Check the regulations and rules
of your local government and be sure to observe them.
CX21LED
2