Axor Front Showerpipe 26020007 Mode d'emploi/Instructions de montage - Page 3
Parcourez en ligne ou téléchargez le pdf Mode d'emploi/Instructions de montage pour {nom_de_la_catégorie} Axor Front Showerpipe 26020007. Axor Front Showerpipe 26020007 16 pages.
S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The product may only be used for bathing, hygienic and body cleaning purposes.
The hot and cold supplies must be of equal pressures.
The product may not be used as a holding handle. A separate handle must be
installed.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
Children as well as adults with physical, mental and ⁄or sensoric impairments must
not use this product without proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
The arm of the shower head is intended only to hold the shower head. Do not load
it down with other objects!
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ The installation dimensions stated in these installation instructions are ideal for
people of approximately 1800 mm in body height. The dimensions can be altered
if required. In this case, pay attention to the fact that a change of installation height
will also change the minimum height, and that the altered mounting dimensions must
be taken into consideration.
⁄ During installation of the product by qualified trained personnel, make sure that the
entire fastening surface is even and smooth (no protruding seams or tile offset), that
the finish of the wall is suitable to apply the product and has no weak points.
⁄ The filter insert must be use to protect the shower against incoming dirt by pipe-
work. Incoming dirt leads to defects or⁄and can damage parts of the shower; such
caused faults voids all liability and guarantee claims.
⁄ Finish assembling and positioning before you connect the mains plug to the power
socket.
⁄ The product is not designed to be used with steam baths!
F A U L T
⁄ Insufficient water
⁄ Crossflow, hot water being forced into cold water pipe, or
vice versa, when mixer is closed
⁄ Spout temperature does not correspond with temperature
set
⁄ Temperature regulation not possible
⁄ Instantaneous heater didn't work with thermostat
A S S E M B L Y (see page 04)
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Centre distance:
Connections R 1⁄2:
⁄ The product is exclusively designed for drinking water!
⁄ Safety against backflow
S Y M B O L D E S C R I P T I O N
C A U S E
⁄ Supply pressure inadequate
⁄ Filters are dirty
⁄ Shower filter seal dirty
⁄ Backflow preventers dirty or leaking
⁄ Thermostat has not been adjusted
⁄ Hot water temperature too low
⁄ thermo cartridge calcified
⁄ Filters are dirty
⁄ check valve hasn't moved back
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 07)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the output
differs from the temperature set on the thermostat.
S A F E T Y F U N C T I O N (see page 07)
The desired maximum temperature for example max. 42º C can be pre-set
thanks to the safety function.
D I M E N S I O N S (see page 09)
F L O W D I A G R A M (see page 09)
overhead shower
Hand shower
O P E R A T I O N (see page 10)
C L E A N I N G (see page 13)
S P A R E P A R T S (see page 15)
M A I N T E N A N C E (see page 08)
The check valves must be checked regularly according to DIN EN 1717 in
accordance with national or regional regulations (at least once a year).
S P E C I A L A C C E S S O R I E S (order as an extra)
#95239000 tile-matching-disk chrome plated (see page 15)
R E M E D Y
⁄ Check water pressure (If a pump has been installed check
to see if the pump is working).
⁄ Clean filter in front of the mixer and on the MTC-thermo
cartridge
⁄ Clean filter seal between shower and hose
⁄ Clean backflow preventers, exchange if necessary
⁄ Adjust thermostat
⁄ Increase hot water temperature to 42 ºC to 65 ºC
⁄ Exchange thermo cartridge
⁄ Clean the filter ⁄ exchange filter
⁄ Exchange check valves
0 3
EN
max. 1 MPa
0,2 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
65°C
max. 70°C ⁄ 4 min
150 ± 12 mm
cold right - hot left