ACCURATE ELECTRONICS 104003C Manuel - Page 4

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} ACCURATE ELECTRONICS 104003C. ACCURATE ELECTRONICS 104003C 10 pages. Line amplifier with loopback module

ACCURATE ELECTRONICS INC
WWW.ACCURATE.ORG
PO BOX 1654 97075-1654 8687 SW HALL BLVD 97008
FIGURE 5. Module Switch Locations.
TONE-LOOPBACK FREQUENCY
3.09 Tone-loopback frequency is selected by means of 10-position DIP
switch (S3) located on the 104003C's daughter pcb. Only 1 switch position
is required to select any 1 of 11 available frequencies. The available loopback
frequencies and settings of switch S3 are summarized in Table 3.
Table 3. Loopback Frequency Selection.
FREQUENCY
(Hz)
2813
2713
2513
2413
1913
1813
1713
1613
1513
1413
1313
*all other S13 switch positions MUST be set to the OFF position.
LOOPBACK LEVELS
3.10 Loopback levels of +16, +9, -16, or –23dB are selected via DIP switch
S4, located on the 104003C's daughter pcb. Loopback level options are
described in paragraph 2.10; the various settings of switch S4 are summarized
in Table 4.
This document contains proprietary information and is supplied for identification, maintenance, engineering evaluation or inspection purposes only and shall not be duplicated or disclosed without written
permission of: ACCURATE ELECTRONICS INC By accepting this document the recipient agrees to make every effort to prevent unauthorized use of this information.
Practice Section 104003C Rev A
S3 SWITCH POSITION
SET TO ON*
All switch positions OFF
1
2
3
4
5
6
7
8
9
10
January 2014
BEAVERTON OR USA 503.641.0118
Table 4. Loopback Level Selection.
Loopback Levels
+16dB
+9dB
-16dB
-23dB
ALIGNMENT
3.11 This alignment subsection is divided into two parts: preliminary
alignment and final alignment verification. In the preliminary alignment
procedure, impedance options are selected, equalization is introduced into the
receive and the transmit channel (if required), and gain or attenuation is
introduced in both the transmit and the receive channel to match the
transmission levels specified on the circuit level record (CLR) card. In the
final alignment verification procedure, the 104003C is placed into service and
end-to-end transmission measurements are made. If the measured levels
differ from those specified on the CLR card, the front-panel TX and RX
LEVEL switches are adjusted to provide the specified levels.
Note: Two condensed preliminary alignment procedures (Figures 6 and 8)
and two condensed final alignment verification procedures (Figures 7 and
9) may be used to facilitate alignment of the 104003C module.
PRELIMINARY ALIGNMENT
3.12 Refer to the CLR card for the required facility port and terminal port
impedances. In general, the 1200-ohm option is used to interface loaded
cable, the 600-ohm option is used to interface nonloaded cable, carrier,
station apparatus, or SF signaling units, and the 150-ohm option is used to
interface short segments of nonloaded cable in applications where a small
degree of slope equalization is required. Use S2 (Main Board) to set the
facility port impedance and S4 (Main Board) to set the terminal port
impedance.
4
FAX 503.646.3903
Switch Positions
S4-1
S4-2
Off
Off
Off
On
On
Off
On
On