Circa Enterprises P6976 Manuel d'installation et d'utilisation - Page 6

Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} Circa Enterprises P6976. Circa Enterprises P6976 12 pages. Correctional institute ringdown telephone

Follow all appropriate electrical codes and use only approved electrical
fittings for the installation.
Choose a wall location that is free of obstructions and permits space for
cable or conduit runs.
Ensure mounting can support 4lbs (1.8kg) and any additional load to which
the telephone may be subjected.
Ensure that none of the electrical connection circuits are live.
Bring Tip, Ring and Ground wiring to the location where the wiring access
opening in the back of the CIR-41 will be when the telephone is installed.
Remove the eight (8) cover screws from the front of the unit and carefully
remove the front cover assembly. NOTE that the handset and all electronics
are attached to the front plate. The front cover may be separated from the
back box by disconnecting the harness plug.
Use the enclosure as a template to locate and drill holes for #8 or M4
mounting screws or other suitable attachments.
Feed Tip, Ring and Ground wiring through the wiring access opening and
secure the unit to the wall.
Attach individual wires from the exchange (Tip/Ring/Ground) to the terminal
strip (Tip & Ring are not polarity sensitive), or plug the RJ11 connector into
the socket if this termination method was chosen. Even if an RJ11
connector is used, an approved earth ground must still be provided to the
ground connection on the terminal strip.
Ensure all connections are tight, then replace and secure the cover.
Connect the telephone into the system.
Test the unit by calling to and from another unit on the exchange.
The CIR-41 Autodialer phone is designed for receiving calls and for
connecting to a single number if the PABX is programmed to perform this
function. Calling out is automatic simply by removing the handset from the
cradle.

Installing the CIR-41

Operating the CIR-41

Page 6
Installation and Operation
CIR41-SWIVEL
See: Figure 2 - Dimensions
Tip: The CIR-41 may be
wired directly to the terminal
block or an RJ11 connector
may be used.
Tip: Use the driver bit
provided to remove the
tamper resistant screws.
See: Figure 3 - Mounting
See: Figure 3 - Mounting
Note: An approved earth
ground must be connected
to the ground position on
the terminal strip regardless
of Tip and Ring wiring
method.