4. Engineering Mode

4.1. Engineering Mode 1: Basic Settings

Pull out the Safety Key, press「Quick Start」+「Speed Fast」then put back the Safety Key to enter
the mode.
4.1.1. Unit setting: Message window show『UNIT - METRIC』, press「Speed Fast」or「Speed
Slow」or「Incline Up」or「Incline Down」can be change to『UNIT - ENGLISH』, press
「Enter」to confirm and to next setting.
4.1.2. Roller size setting: Message window show『ROLLER SIZE 70』(default=70mm), press
「Speed Fast」 or 「Speed Slow」 to set, the range is 50~90mm, press「Enter」 to confirm
and to next setting.
4.1.3. Motor stop manner: Message window show 『MOTOR CONTROL』, press 「Speed Fast」
or 「 Speed Slow」 can be change to 『MOTOR FREE』 , press 「Enter」 to confirm and to next
setting.( 『MOTOR CONTROL』=Slow down to lowest speed by motor control while
stop; 『MOTOR FREE』= cut off the motor power while stop)
4.1.4. Min speed setting: Message window show『MIN SPEED 0.8』, press 「Speed Fast」
or「Speed Slow」to set the min speed, setting range:0.3~1.2KPH / 0.2~0.7MPH, press
「Enter」to confirm and to next setting.
4.1.5. Max speed setting: Message window show『MAX SPEED 20.0』, press 「Speed Fast」
or「Speed Slow」to set the min speed, setting range:8~25KPH / 5~15.5MPH, press
「Enter」to confirm and back to idle mode.

4.2. Engineering Mode 2: Used Information Management

Pull out the safety key, press 「 Quick Start」 + 「Speed Slow」 then put back the safety key to enter
mode.
4.2.1. Time window show total used time 0:00(H:M)~99:59(H:M)~100(H)~9999(H), over 9999
display 9999.
4.2.2. Distance window & dot-matrix show total used distance information, distance window
show 0.0~99.9~100~999. dot-matrix show 0~99K.(distance window show 555 and
dot-matrix window show 2K, the total distance=2000+555=2555 km/mil)
4.2.3. Heart Rate window show software version『V X.XX』.

4.3. Engineering Mode 3: Erase The Custom Settings To Default Value

Pull out the safety key, press 「Stop」 for 5 seconds, message window show 『ARE YOU SURE』 ,
press Enter to erase the custom settings to default value.
4.4. Engineering Mode 4: Real Time Speed & Incline Parameter
Press 「Incline Up」 + 「Speed Slow」 for till a beep sound after start. Speed window displays the
real time speed what feedback from speed sensor, incline window displays the incline
position parameter.