2. Error Signal Check and Solutions
Item
Error Message
1.
COMMUNICATION FAIL
2.
DC BUS ERROR
3.
DCV VOLT OVERLOAD
4.
DCV VOLT OVERVOLT
Document:
Service Manual
Description:
Elliptical/Upright Bike/ Recumbent Bike
Model:
E7/B8/R8
Descriptions
CAUSE: Communication timeout. This error message
pops up if console and generator lose communication for
over 90 seconds.
SOLUTION:
- Check that the console and generator are connected
properly.
- If the connection is correct, please replace the console or
generator.
CAUSE: The generator cannot transform AC power to DC
power.
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error message
pops up again, replace the generator.
CAUSE: The voltage of DC generator is too high (over
300V for 3 seconds). User may be peddling too fast
(normal peddling speed should be under 180 RPM).
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error message
pops up again, replace the generator.
CAUSE: The voltage of DC generator is too high (over
300V for 3 seconds). User may be peddling too fast
(normal peddling speed should be under 180 RPM).
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error message
pops up again, replace the generator.
8
Display Type:
LED
Page:
8
of 16
Release Date:
2017/08/31