Item
Error Message
1.
MV VOLT OVERLOAD
2.
CMP CURR OVERLOAD
3.
CMP CURR OVERCURR
4.
SHORT CIRCUIT
5.
CURRENT STATE NG
Document:
Service Manual
Description:
Elliptical/Upright Bike/ Recumbent Bike
Model:
E7/B8/R8
Descriptions
CAUSE: The generator output voltage is overloaded.
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error message
pops up again, replace the generator.
CAUSE: The output current of the generator is over 3amps
for 3 seconds.
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error message
pops up again, replace the generator.
CAUSE: The output current of generator is over 3.5amps
for 1 second.
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error message
pops up again, replace the generator.
CAUSE: The IGBT of generator is short circuit.
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error message
pops up again, replace the generator.
CAUSE: The output circuit of the generator is abnormal or
the coil did not connect to the controller.
SOLUTION:
- Check the coil connection.
- If coil connection is correct, replace the generator.
9
Display Type:
LED
Page:
9
of 16
Release Date: