Digicom Archimede SMS Manuel opérationnel - Page 12

Parcourez en ligne ou téléchargez le pdf Manuel opérationnel pour {nom_de_la_catégorie} Digicom Archimede SMS. Digicom Archimede SMS 18 pages. Remote alarm system

Digicom Archimede SMS Manuel opérationnel
Example of a configuration message is as follows :
#9#Power Failure #T#+4467895657488#+4473263748596#+445476576879888#
After sending this message the receiving Archimedes Pwr LED will flash for 5 secs to
indicate the message has been received and stored .This follows by a rapid flashing of the
Pwr Led for a further 5 secs then constantly on. In the event that the Pwr LED continues
to flash check the SMS message for any Syntax errors.
3.1.4 Configuring the Output Relay
The Archimede SMS has the capability of controlling an external device via an internal
relay whose contact outputs are on pins 19 and 20. This contact is normally open and can
be closed when the correct SMS message is received by the unit. This can be used via a
contact breaker or switch to shut a valve or turn on/off a switch .
To configure the output relay function an SMS message of the following structure must be
sent to the Archimede.
# 10 # Name # Tel 1 # Tel 2 # Tel 3 # Tel 4 # Tel 5
Field
#
10
#
Name of contact
#
No Tel 1
#
No Tel 2
#
No Tel 3
#
No Tel 4
#
No Tel 5
#
No Tel 6
#
• Note * The telephone number must always be inserted with its international code ie
+44 for UK, +49 for Germany , +33 for France etc
• All SMS messages must end with a # sign
Quantiy Characters
1
2
1
Max 20
1
20 Max
1
20 Max
1
20 Max
1
20 Max
1
20 Max
1
20 Max
1
Description
Delimit Character
10 is the memory location for Output relay
Delimit Character
Name (Message) to be sent to operate contact
Delimit Character
1st Tel Number allowed to send control
message
Delimit Character
2nd Tel Number allowed to send control
message
Delimit Character
rd
3
Tel Number allowed to send control
message
Delimit Character
4th Tel Number allowed to send control
message
Delimit Character
5th Tel Number allowed to send control
message
Delimit Character
6th Tel Number allowed to send control
message
Delimit Character
# Tel 6 #
12