PROBLEM
Insufficient water flow to
chlorinator
Insufficient chlorine in pool
Excess chlorine in pool
Air leaks
Chlorinator overflow
The Easiflo Chlorine Feeder comes with a 12 month warranty from the date of installation. In order for the warranty to be validated
the Warranty Registration Document W2 must be completed and returned to Arch Water Products, Wheldon Road, Castleford WF10
2JT
TROUBLESHOOTER'S GUIDE
CAUSE
Check water flow through nozzles. If there is scale
build-up perform de-scale operation
Inlet Shutoff Valve closed
Emergency Shut Off Valve in closed position
Solenoid Valve not operating (auto control system
only)
Feed rate/output too low
Chlorinator empty
No inlet water flow
Outlet/Shutoff Valve closed
Clogged Discharge Tubing
Briquettes stuck together
Clogged Briquette Tank Grid
Clogged Venturi System
Closed valves in venturi system
Automatic Controller Problem
Feed rate/output too high
Discharge Tubing not properly installed in fittings
Discharge Valve seat failure
Scale prevents Discharge Valve from properly
seating
Pinched O-rings in Tubing Connectors
Discharge Tubing clogged
Clogged venturi system
Insufficient outlet suction
Emergency shutoff valve failure
SECTION B
Rinse out dissolving cup, soak in a 2 parts water to 1
part hydrochloric acid and allow scale to dissolve.
Open Inlet Shutoff Valve
If ESV Valve is stuck, lower gently to reset
Check with Dealer
Increase feed rate by increasing inlet flow.
Refill Briquette Hopper with Easiflo
See insufficient water flow section
Open Outlet Shutoff Valve
Refer to Section A or Replace discharge tubing
Tap side of Briquette Tank to loosen
Refer to Section A
Remove venturi – soak in tub with mixture of 10 parts
water and 1 part hydrochloric acid solution.
Open venturi system valves
Refer to automatic controller manual
Decrease feed rate by reducing inlet flow
Reinstall Discharge Tubing
Replace Discharge Valve Arm.
Remove Discharge Valve Assembly and soak in
solution of 2 parts water to 1 part hydrochloric acid to
remove scale
Inspect O-rings on discharge side of feeder
Refer to Section A or Replace Discharge tubing.
See clogged venturi system solution
Check with Dealer
Check with Dealer
WARRANTY POLICY
5
SOLUTION
®
Briquettes