Aybey Elektronik CCL-P Manuel de programmation et d'installation - Page 2
Parcourez en ligne ou téléchargez le pdf Manuel de programmation et d'installation pour {nom_de_la_catégorie} Aybey Elektronik CCL-P. Aybey Elektronik CCL-P 5 pages. Custom design rgb lcd display board
GENERAL FEATURES
CCL/CCT is a custom-design Horizontal RGB LCD display system designed to use for Lift cabin and
landing push-buttons. It needs 12-24V DC supply. CCL-S and CCT gets all information from
CANBus. CCL-S is used for fault tolerant applications, CCT is used for high speed applications. CCL-
P can be applied up to 64 stops with 6 gray/binary code inputs as M0,...,M5 or counter systems inputs
as M0, 817, 818 and 7-Segment inputs. They also includes 4 signal inputs as 31 (Down Arrow), 32
(Up Arrow), 35 (Overload) and 39 (Inspection). Galvanically isolated inputs can be driven by positive
or negative voltage. Reverse of input voltage is selected from common terminals COM1 and COM2.
Full character screen and related graphical symbols are shown below:
After initialization, software version number and ID (in CANBus) is displayed first. Then inputs are
evaluated and related character(s) are displayed according to stored settings. If no input is connected
or all connected inputs are passive then floor 0 character(s) are displayed. (In 7-Segment Mode if no
input is connected or connection is wrong then no character displays; if no communication established
in CANBus mode, then "CE" displays)
When signal input(s) are activated or serial communication established then related symbol is
displayed on left side. Floor information signal inputs drive 2 digit characters, indicating floor
information. For floor indicating displays, all capital letters, numbers, - sign in dot-matrix segments
format can be chosen as left and right digit for up to 64 floors.
F/7.5.5.02.89 R:2
CCL
2