CREE LIGHTING THE EDGE Series Guide de démarrage rapide - Page 2

Parcourez en ligne ou téléchargez le pdf Guide de démarrage rapide pour {nom_de_la_catégorie} CREE LIGHTING THE EDGE Series. CREE LIGHTING THE EDGE Series 2 pages. Led flood side mount

CREE LIGHTING THE EDGE Series Guide de démarrage rapide
4
ELECTRICAL CONNECTIONS
Make the following Electrical Connections:
a. Connect supply ground wire to ground wire from Fixture
Canopy and the ground wire from the Fixture Cord using
supplied wire nut.
b. Connect supply line conductor to black wire from Fixture
Cord using supplied wire nut.
c. Connect supply neutral conductor to white wire from Fixture
Cord using supplied wire nut.
© 2019 Cree Lighting, A company of IDEAL INDUSTRIES. All rights reserved. For informational purposes only. Content is
subject to change. See www.creelighting.com/warranty for warranty and specifications. Cree
trademarks of Cree, Inc. THE EDGE
is a registered trademark of Cree Lighting, A company of IDEAL INDUSTRIES.
®
2 of 2
1/2" and 2" (51 mm)
Adjustable Fitter Positions
FIXTURE AIMING
STEP 1:
Adjust fixture to desired aiming angle. The fixture may be aimed at
2-1/2° increments. Markings are located on outside of fitter for ease
of aiming. See Figure 4.
STEP 2:
Tighten 3/8" bolt in fitter splice compartment to approximately 19
ft.lbs. (25 N•m).
STEP 3:
Replace the lower fitter compartment cover and tighten screws,
making sure not to pinch the O-ring
LINE
OR HOT 1
GREEN
NEUTRAL
OR HOT 2
VIOLET
GREY
®
and the Cree logo are registered
LUMINAIRE
LINE-BLACK
GROUND-GREEN
NEUTRAL-WHITE
DIM (+) VIOLET
DIM (-) GREY
www.creelighting.com
CI317X02R0_B