Connector
Connection of S1
Mounting
Size
Weight
Colour
Reaction time (in/out)
Minimum off time
Safety / Harmonized Standards
Conformity
EN 62061
EN ISO 13849-1
EN 954-1
Certificates

Dimensions

Vital 1 dimensions
NB: All measurements in millimetres.
2TLC172156M0201, rev. C
2016-07-04
Two connection blocks with 7 terminals each (detachable)
Max tightening torque: 1 Nm
Max connection area:
Solid conductors: 1 x 4 mm
Conductor with socket contact: 1 x 2.5 mm
Odd number of sensors: S1 not connected
Even number of sensors: S1 connected to B1 (+24 VDC)
35 mm DIN rail
120 x 84 x 22.5 mm (L x W x H)
~ 220 g
Black and beige
At power on: < 65 ms
When activating (in-output): < 40 ms
When deactivating (in-output): < 48 ms
At power loss: < 55 ms
80 ms
European Machinery Directive 2006/42/EC
EN ISO 12100:2010, EN 954-1:1996/EN ISO 13849-1:2008, EN 62061:2005, EN 60204-
1:2006+A1:2009, EN 60664-1:2007, EN 61000-6-2:2005, EN 61000-6-4:2007, EN 61496-
1:2004+A1:2008, EN 60947-5-1
-8
SIL3, PFH
: 2.74*10
, MTTF
> 100 years
d
d
Performance level: PL e, category 4
-8
PFH
: 2.74*10
, MTTF
> 100 years
D
d
Category 4
TÜV Nord, cCSAus, CCC
18
2
2
/ 2 x 1.5 mm
/ 12 AWG
2
2
/ 2 x 1 mm
www.abb.com/jokabsafety