Digikeijs DR5033 Manuel d'instruction - Page 7
Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} Digikeijs DR5033. Digikeijs DR5033 18 pages. 3-ampere, h-bridge dcc booster
Également pour Digikeijs DR5033 : Manuel (10 pages), Manuel d'instruction (18 pages)
DR5033 DIGIBOOST
3.1 LocoNet® Variables (LNCV) Table
LNCV Description
0
Loconet module address
Firmware version (1000 = 1,000)
1
(Value can only be read)
3
Configuration LNCV
Temperature of the H-bridge in degrees °C
6
(Value can only be read)
Current load in %
7
(Value can only be read)
Turnout address for booster Individual switch-off
8
Waiting time until restart after short circuit.
11
The default value corresponds to approx. one 3/4 second
(750 ms). (Setting is done in three millisecond steps.)
3.2 Description Configuration LNCV
With the LNCV 3 the behaviour (short-circuit behaviour, start behaviour, automatic reverse polarity, etc.) of the booster can be adapted.
Bit
Wert Description
0
Not used
0
1
Not used
0
Track Out active as soon as an input signal is detected.
1
Track Out active as soon as the GO/Stop button of the control
2
unit is pressed or the connected switching address (LNCV 8) is
switched to green.
Booster does not send 'GPON/GPOFF' L.NET report on short
0
circuit. Automatic short-circuit repair is enabled.
2
Booster sends 'GPON/GPOFF' L.NET report to headquarters. The
4
central determines when the track out is switched on again.
0
Not used
3
8
Not used
www.digikeijs.com
® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
Stand 2021-07-06
range
1-9999
-
siehe unten
0-150
0-100
0-2048
64-30000
Default
LNCV Description
Waiting time after automatic polarity reversal of the track
1
12
out before a short circuit is reported to the control unit.
(Setting in 3 millisecond steps.)
Waiting time before polarity reversal or short-circuit signal.
-
13
(Setting in 3 millisecond steps.)
Optional switching address for polarity reversal of the out-
92
14
put
-
15
Polarity reversal ON for feedback A
-
16
Polarity reversal ON for feedback B
0
17
Polarity reversal OFF for feedback D
244
18
Polarity reversal OFF for feedback E
Default
Bit
Wert Description
Booster does not send a special LocoNet® message in case of
0
short-circuit shutdown.
0
4
Booster sends a LocoNet® message in case of a short circuit so
16
that the central unit can display which booster has been
switched off.
0
Track Out active without output polarity reversal (blue LED off)
0
5
32
Track Out active Output reversed polarity (blue LED on)
0
Automatic polarity reversal off
4
6
64
Automatic polarity reversal on
0
Not used
8
7
128
Not used
range
Default
32-250
48
16-250
32
0-2048
0
0-2048
0
0-2048
0
0-2048
0
0-2048
0
Default
16
0
64
0
P 7