VENTING YOUR OVEN:
1.
The purpose of ventilating hoods is to direct and
capture smoke, grease-laden vapors, heat, odors, or
fumes.
2.
Low temperature equipment (maximum temperature
250°F/121°C) does not produce heat, odors, fumes,
grease-laden vapors or smoke and is not required to be
vented.
UNIT SPECIFICATIONS: All units use three (3) elements (2670 watts each).
All units are rated 8200 watts. Water units have one (1) immersion element (1850 watts).
MODEL NOS.
CONVECTION OVENS
CO151FWUA12B2081
CO151FWUA12B2401
CO151FWUA12B2083
CO151FWUA12B2403
RETHERM OVENS
RO151FWUA18B2081
RO151FWUA18B2401
RO151FWUA18B2083
RO151FWUA18B2403
RO151FW1332B2081
RO151FW1332B2401
RO151FW1332B2083
RO151FW1332B2403
HALF-SIZE OVENS
CO151HWUA6B2081
CO151HWUA6B2401
CO151HWUA6B2083
CO151HWUA6B2403
CO151XWUA5B2081
CO151XWUA5B2401
CO151XWUA5B2083
CO151XWUA5B2403
All models are designed for AC Service. Model numbers may have the letters: P, L, M, Z or S.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

INSTALLATION INSTRUCTIONS

ELECTRICAL SPECS
(AC SERVICE)
Volts
Ph
208
1
240
1
208
3
240
3
208
1
240
1
208
3
240
3
208
1
240
1
208
3
240
3
Are rated at 4700 watts (Three [3] heaters at 1470 watts each)
208
1
240
1
208
3
240
3
208
1
240
1
208
3
240
3
3.
Most jurisdictions consider our low-temperature ovens
(maximum temperature is 350°F/177°C) as low-heat
appliances not requiring vent hoods.
4.
Installation must conform with local codes. The
authority having jurisdiction of enforcement of
the codes will have the responsibility for making
interpretations of the rules.
ELEC. LOAD
Hz.
Amps
Volts
60
39
208
60
34
240
60
23
208
60
20
240
60
39
208
60
34
240
60
23
208
60
20
240
60
39
208
60
34
240
60
23
208
60
20
240
60
24
208
60
21
240
60
15
208
60
13
240
60
24
208
60
21
240
60
15
208
60
13
240
Ovens
Rev. 10 (4/08)
POWER SUPPLY REQUIREMENT
ALL 3 PHASE IS 3 WIRE + GROUND
Amps
Ph
Volts
50
1
208
50
1
240
30
3
208
30
3
240
50
1
208
50
1
240
30
3
208
30
3
240
50
1
208
50
1
240
30
3
208
30
3
240
30
1
208
30
1
240
20
3
208
20
3
240
30
1
208
30
1
240
20
3
208
20
3
240
FL-2270
Page 3 of 13
NEMA
6-50P
6-50P
L15-30P
L15-30P
6-50P
6-50P
L15-30P
L15-30P
6-50P
6-50P
L15-30P
L15-30P
6-30P
6-30P
L15-20P
L15-20P
6-30P
6-30P
L15-20P
L15-20P