PROGRAMMING INSTRUCTIONS
Assign User Credentials
Up to 20 user credentials (User Key or RFID credential) may be assigned to each lock.
1
Present hand to wake up the
lock.
Express Register User and Manager Credentials
The Programming Key can quickly program multiple locks to operate with the same user and manager credentials.
1
sec
Go to a lock already programmed to
operate with the user and manager
credentials.
Insert Programming Key and hold for a
total of 15 seconds.
A two-tone beep will be heard after 5
seconds,.
3
Insert the Programming Key to program
each lock to operate with the same user
and manager credentials. Two sets of
two-tone beeps will be heard and the
LED will flash once to indicate successful
programming.
*The Programming Key will continue to function in express registration mode until it is used to operate a lock.
4
P R O DU CT GU I D E
Touch-Free RFID | Basic & Advanced
2
sec
Insert a valid Manager Key for 5
seconds.
A two-tone beep will be heard.
Remove the Manager Key.
The LED will flash.
2
x1
Then followed by 2 sets of two-tone beeps
after 10 seconds.
Then followed by 3 sets of two-tone beeps
after 15 seconds.
The LED will flash.
4
End express registration.*
Go to any programmed lock, then present
hand to lock.
3
or
Insert each User Key or present
each User RFID credential one
at a time.
Two sets of two-tone beeps
will be heard for each user
credential assigned to the lock.
3
x2
sec
x3
sec
Remove and reinsert the Programming
Key.
A two-tone beep will be heard and the
LED will turn off.
5
Then insert the programming key to
operate the lock.
4
Insert a valid Manager Key.
A two-tone beep will be heard
and the LED will turn off.