1. Default User Code: 0
After the 4 x AA batteries are installed, without altering any settings, press "0" then "#" to open the
door directly. Once the first user code is programmed, the default code of '0' will no longer unlock the
handle.
2. Changing Master Code:
2.1 Master code: Adding and deleting of Guest Code/TM Key Users.
The Master code cannot be used for unlocking the door
2.2 The default Master code: 123456
2.3 Master codes should be between 4-8 digits.
2.4 Prior to modifying the Master code:
2.41 Reset the Master code:
Operating instructions
Loosen the two screws on the rear panel of
the digital lock, remove the rear panel, press
the button below the batteries for ten
seconds.
Note: This operation will clear all Guest Code/TM Key Users
2.42 Prepare the New Master Code, 4-8 digits (eg: 12345678)
Changing the Master code
2.5
Operating instructions
1 Press "#" to start the lock
2 Input the Default Master code: 123456,
then press "#"
3 Within ten seconds (before the indicator
light switches off) input "11" then "#"
4 Input the New Master Code, (4-8digits)
then "#"
5 Input the New Master Code again, then "#"
confirm.
Add Normal Users
3.
3.1 Maximum of 200 Users, including Code Users, TM Key Users, and Code&TM Key Users.
3.2 Set the User Group before adding the Normal User, each Group represents one User.
Group No. = 3 digits, from 001 to 200, groups cannot be reused.
# Master Code # / Program Code # / Group No.# / Guest Open Door Code# / ##
(11#)
(01#)
Lock status
One "Beep" and red light will flash, After ten seconds,
lock will "Beep" two times, and the blue indicator light
will flash. Master code is now reset to 123456.
Lock status
"Beeps" twice, keypad lights up, blue light flashes.
Lock status as above
Lock status as above
Lock status as above
"Beeps" four times, indicator light switches off. New
Master Code is set.